High‐Performance Flexible and Printed Graphene‐Field Effect Biosensor for Ferritin Detection

Abstract A flexible and printed field‐effect biosensor with a graphene channel (Gr‐FET biosensor) is designed and characterized to detect ferritin. The biosensor offers an onboard Ag/AgCl gate to give stable transfer characteristics with a significantly low gate leakage current of 0.06% of the minimum drain current. Further, the proposed Gr‐FET shows 1.5–3 times higher transconductance ( g m ) with a value of g m,hole up to 400 µS and g m,electron up to 250 µS, compared to the reported printed electrolyte‐gated Gr‐FET on flexible substrates. The Gr‐FET operation is also optimized to have a minimal hysteresis effect for reliable sensing operation. The Gr‐FET shows fairly linear characteristics at a low ferritin concentration (0.05–0.5 µg L −1 ) with sensitivity as high as ≈230 mV/(µg L −1 ) and a very low limit of detection (LOD) ≈27 ng L −1 . Given the cost‐effective fabrication process and scalability, the proposed printed Gr‐FET biosensor can be deployed on a large scale for early diagnosis of iron deficiency anemia.

Authors

Institutions

Publication Details

Journal
Advanced Materials Technologies
Published
2024-11-27
DOI
https://doi.org/10.1002/admt.202401292
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High‐Performance Flexible and Printed Graphene‐Field Effect Biosensor for Ferritin Detection

Mitradip Bhattacharjee, Kamalesh Tripathy
1 citations
Advanced Materials Technologies
Advanced biosensing and bioanalysis techniques
0.23
article

High‐Performance Flexible and Printed Graphene‐Field Effect Biosensor for Ferritin Detection

Mitradip Bhattacharjee, Kamalesh Tripathy
article en
1 citations

Abstract

Abstract A flexible and printed field‐effect biosensor with a graphene channel (Gr‐FET biosensor) is designed and characterized to detect ferritin. The biosensor offers an onboard Ag/AgCl gate to give stable transfer characteristics with a significantly low gate leakage current of 0.06% of the minimum drain current. Further, the proposed Gr‐FET shows 1.5–3 times higher transconductance ( g m ) with a value of g m,hole up to 400 µS and g m,electron up to 250 µS, compared to the reported printed electrolyte‐gated Gr‐FET on flexible substrates. The Gr‐FET operation is also optimized to have a minimal hysteresis effect for reliable sensing operation. The Gr‐FET shows fairly linear characteristics at a low ferritin concentration (0.05–0.5 µg L −1 ) with sensitivity as high as ≈230 mV/(µg L −1 ) and a very low limit of detection (LOD) ≈27 ng L −1 . Given the cost‐effective fabrication process and scalability, the proposed printed Gr‐FET biosensor can be deployed on a large scale for early diagnosis of iron deficiency anemia.

Advanced Materials TechnologiesVol. 10(7)
Indian Institute of Science Education and Research, Bhopal (IN)
Clean water and sanitation
Openalex Percentile: Top 41%
Advanced biosensing and bioanalysis techniques
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.