The Association Between the Hemodynamics in Anomalous Origins of Coronary Arteries and Atherosclerosis: A Preliminary Case Study Based on Computational Fluid Dynamics

Patients with anomalous coronary artery origins (AOCA) exhibit a higher risk of atherosclerosis, where even minimal stenosis may lead to adverse cardiovascular events. However, the factors contributing to this heightened risk in AOCA patients remain unclear. This study aimed to investigate whether an AOCA patient is more prone to stenosis occurrence and its progression in view of hemodynamics. A patient whose left circumflex artery originated from the right coronary sinus with a mild stenosis in the left anterior descending (LAD) artery and a healthy individual were included in this study. Two additional models were developed by removing stenosis from the patient model and adding a corresponding stenosis to the healthy model. Additionally, the inlet flow waveforms for the left and right coronary arteries were swapped in both the patient and healthy models. Results indicated that the AOCA patient without stenosis demonstrated higher wall pressure (LAD: 95.57 ± 0.73 vs. 93.86 ± 0.50 mmHg; LCX: 94.97 ± 0.98 vs. 93.47 ± 0.56 mmHg; RCA: 96.23 ± 0.30 vs. 93.86 ± 0.46 mmHg) and TAWSS (LAD: 24.41 ± 19.53 vs. 13.82 ± 9.87 dyne/cm<sup>2</sup>, <i>p</i> < 0.0001; LCX: 27.21 ± 14.51 vs. 19.33 ± 8.78 dyne/cm<sup>2</sup>) compared to the healthy individual, with similar trends also observed in stenotic conditions. Significant changes in the LCX flow distribution were also noted under varying pulsatile conditions (LCX: 18.28% vs. 9.16%) compared to the healthy individual. The high-pressure, high-shear hemodynamic environment in AOCA patients predisposes them to atherosclerosis, and the unique geometry exacerbates hemodynamic abnormalities when stenosis occurs. Clinicians should closely monitor AOCA patients with stenosis to prevent adverse cardiovascular events.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2024-11-26
DOI
https://doi.org/10.3390/bioengineering11121196
Citations
4
Primary Topic
Coronary Artery Anomalies
Type
article
Field-Weighted Citation Impact
1.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Association Between the Hemodynamics in Anomalous Origins of Coronary Arteries and Atherosclerosis: A Preliminary Case Study Based on Computational Fluid Dynamics

Tinghui Zheng, Yuhao Wei, Haoyao Cao
4 citations
Bioengineering
Coronary Artery Anomalies
1.68
article

The Association Between the Hemodynamics in Anomalous Origins of Coronary Arteries and Atherosclerosis: A Preliminary Case Study Based on Computational Fluid Dynamics

Tinghui Zheng, Yuhao Wei, Haoyao Cao
article en
4 citations

Abstract

Patients with anomalous coronary artery origins (AOCA) exhibit a higher risk of atherosclerosis, where even minimal stenosis may lead to adverse cardiovascular events. However, the factors contributing to this heightened risk in AOCA patients remain unclear. This study aimed to investigate whether an AOCA patient is more prone to stenosis occurrence and its progression in view of hemodynamics. A patient whose left circumflex artery originated from the right coronary sinus with a mild stenosis in the left anterior descending (LAD) artery and a healthy individual were included in this study. Two additional models were developed by removing stenosis from the patient model and adding a corresponding stenosis to the healthy model. Additionally, the inlet flow waveforms for the left and right coronary arteries were swapped in both the patient and healthy models. Results indicated that the AOCA patient without stenosis demonstrated higher wall pressure (LAD: 95.57 ± 0.73 vs. 93.86 ± 0.50 mmHg; LCX: 94.97 ± 0.98 vs. 93.47 ± 0.56 mmHg; RCA: 96.23 ± 0.30 vs. 93.86 ± 0.46 mmHg) and TAWSS (LAD: 24.41 ± 19.53 vs. 13.82 ± 9.87 dyne/cm<sup>2</sup>, <i>p</i> < 0.0001; LCX: 27.21 ± 14.51 vs. 19.33 ± 8.78 dyne/cm<sup>2</sup>) compared to the healthy individual, with similar trends also observed in stenotic conditions. Significant changes in the LCX flow distribution were also noted under varying pulsatile conditions (LCX: 18.28% vs. 9.16%) compared to the healthy individual. The high-pressure, high-shear hemodynamic environment in AOCA patients predisposes them to atherosclerosis, and the unique geometry exacerbates hemodynamic abnormalities when stenosis occurs. Clinicians should closely monitor AOCA patients with stenosis to prevent adverse cardiovascular events.

BioengineeringVol. 11(12)
Sichuan University (CN), Yibin University (CN)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 14%
Coronary Artery Anomalies
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.