Optimizing Scan Range in Computed Tomography of Kidneys, Ureters, and Bladder: A Retrospective Study on Reducing Overscanning

<i>Background and Objectives</i>: Computed tomography of the kidneys, ureters, and bladder (CT KUB) is essential for evaluating urinary stones but also exposes patients to significant radiation. The scanning field should be minimized to only the necessary area to limit this radiation exposure. This study aims to assess the extent of CT KUB overscanning in renal colic procedures and identify the appropriate vertebral level for starting CT KUB scans. <i>Materials and Methods</i>: A retrospective analysis of 299 adult patients who underwent CT KUB examinations for kidney stone assessment was performed. To assess overscanning, the number of excess slices above the pole of the highest kidney and under the pubic symphysis was measured on the axial image of each patient. To allow for potential human error, a maximum acceptable level of overscanning was set at 10%. <i>Results</i>: This study found that only 31% of the scans met the target of less than 10% of overscanning superior to the highest kidney and inferior to the pubic symphysis. In comparison, overscanning was present in 69% of the scans, mainly at a superior level, resulting in higher radiation exposure for patients. <i>Conclusions</i>: A significant number of the scans exhibited unnecessary overscanning beyond the highest kidney, prompting us to propose using the upper border of the T10 vertebral body as a potential reference point to establish the upper margin for a CT KUB scan. This study suggests using T10 and the pubic symphysis as reliable landmarks to accurately determine the scan length. Starting CT KUB scans from the T10 vertebral body to the pubic symphysis allows for imaging of the entire urinary tract, minimizing unnecessary overscanning and reducing patient irradiation.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2024-11-26
DOI
https://doi.org/10.3390/medicina60121952
Citations
4
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Scan Range in Computed Tomography of Kidneys, Ureters, and Bladder: A Retrospective Study on Reducing Overscanning

Khaled Alenazi, Haitham Alahmad, Mohammad Alarifi, Ahmad Abanomy et al.
4 citations
Medicina
Radiation Dose and Imaging
1.62
article

Optimizing Scan Range in Computed Tomography of Kidneys, Ureters, and Bladder: A Retrospective Study on Reducing Overscanning

Khaled Alenazi, Haitham Alahmad, Mohammad Alarifi, Ahmad Abanomy, Mansour Almanaa, Ali Bin Owien
article en
4 citations

Abstract

<i>Background and Objectives</i>: Computed tomography of the kidneys, ureters, and bladder (CT KUB) is essential for evaluating urinary stones but also exposes patients to significant radiation. The scanning field should be minimized to only the necessary area to limit this radiation exposure. This study aims to assess the extent of CT KUB overscanning in renal colic procedures and identify the appropriate vertebral level for starting CT KUB scans. <i>Materials and Methods</i>: A retrospective analysis of 299 adult patients who underwent CT KUB examinations for kidney stone assessment was performed. To assess overscanning, the number of excess slices above the pole of the highest kidney and under the pubic symphysis was measured on the axial image of each patient. To allow for potential human error, a maximum acceptable level of overscanning was set at 10%. <i>Results</i>: This study found that only 31% of the scans met the target of less than 10% of overscanning superior to the highest kidney and inferior to the pubic symphysis. In comparison, overscanning was present in 69% of the scans, mainly at a superior level, resulting in higher radiation exposure for patients. <i>Conclusions</i>: A significant number of the scans exhibited unnecessary overscanning beyond the highest kidney, prompting us to propose using the upper border of the T10 vertebral body as a potential reference point to establish the upper margin for a CT KUB scan. This study suggests using T10 and the pubic symphysis as reliable landmarks to accurately determine the scan length. Starting CT KUB scans from the T10 vertebral body to the pubic symphysis allows for imaging of the entire urinary tract, minimizing unnecessary overscanning and reducing patient irradiation.

MedicinaVol. 60(12)
King Faisal Specialist Hospital & Research Centre (SA), King Saud University (SA)
King Saud University
Good health and well-being
Openalex Percentile: Top 15%
Radiation Dose and Imaging
1.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.