Replication of clinical prosthetic sockets for research purposes

For research in the field of prosthetics to be representative of clinical realities, studies require inclusion of clinical standard prosthetic sockets. This necessitates involvement of a prosthetist (clinical professional) in any study, which is to truly explore the effectiveness of existing or novel prosthetic technologies. Unfortunately, there is a global shortage of prosthetists. With many technological advances in upper-limb prosthetics coming from engineering focused labs, it is unsurprising that studies are frequently conducted with anatomically intact individuals. In this paper, we present a method to clone the shape of a clinical standard prosthetic socket for research purposes. The technique uses silicone to capture the socket shape; this is then converted into a plaster mold, which can be used to manufacture an identically shaped socket using standard clinical manufacturing techniques. The whole process can be achieved without the involvement of a prosthetist. To validate the proposed technique, molds from an original socket and socket clone were 3D scanned. The distance between the aligned meshes were measured using CloudCompare software. The mean distance between the points on the 2 meshes was 0.16 mm (standard deviation 0.38 mm). This proof-of-concept study demonstrates that the proposed new approach to cloning a clinical standard prosthetic socket is feasible and accurate. This technique will facilitate improvements in the assessment of prosthetic technologies. The process is nondestructive, thus also opening opportunities for socket design and electrode placement research with the removal of confounding factors relating to socket shape.

Authors

Institutions

Publication Details

Journal
Prosthetics and Orthotics International
Published
2024-11-27
DOI
https://doi.org/10.1097/pxr.0000000000000386
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Replication of clinical prosthetic sockets for research purposes

Matthew Dyson, Alix Chadwell, Laurence Kenney, Jennifer Olsen et al.
Prosthetics and Orthotics International
Prosthetics and Rehabilitation Robotics
article

Replication of clinical prosthetic sockets for research purposes

Matthew Dyson, Alix Chadwell, Laurence Kenney, Jennifer Olsen, Michael Prince
article en

Abstract

For research in the field of prosthetics to be representative of clinical realities, studies require inclusion of clinical standard prosthetic sockets. This necessitates involvement of a prosthetist (clinical professional) in any study, which is to truly explore the effectiveness of existing or novel prosthetic technologies. Unfortunately, there is a global shortage of prosthetists. With many technological advances in upper-limb prosthetics coming from engineering focused labs, it is unsurprising that studies are frequently conducted with anatomically intact individuals. In this paper, we present a method to clone the shape of a clinical standard prosthetic socket for research purposes. The technique uses silicone to capture the socket shape; this is then converted into a plaster mold, which can be used to manufacture an identically shaped socket using standard clinical manufacturing techniques. The whole process can be achieved without the involvement of a prosthetist. To validate the proposed technique, molds from an original socket and socket clone were 3D scanned. The distance between the aligned meshes were measured using CloudCompare software. The mean distance between the points on the 2 meshes was 0.16 mm (standard deviation 0.38 mm). This proof-of-concept study demonstrates that the proposed new approach to cloning a clinical standard prosthetic socket is feasible and accurate. This technique will facilitate improvements in the assessment of prosthetic technologies. The process is nondestructive, thus also opening opportunities for socket design and electrode placement research with the removal of confounding factors relating to socket shape.

Prosthetics and Orthotics InternationalVol. 49(3)
University of Southampton (GB), University of Salford (GB), Newcastle University (GB)
University of Salford Manchester, National Institute for Health and Care Research, Invention for Innovation
Industry, innovation and infrastructure
Openalex Percentile: Top 80%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.