External validation and performance analysis of a deep learning-based model for the detection of intracranial hemorrhage

PurposeWe aimed to investigate the external validation and performance of an FDA-approved deep learning model in labeling intracranial hemorrhage (ICH) cases on a real-world heterogeneous clinical dataset. Furthermore, we delved deeper into evaluating how patients' risk factors influenced the model's performance and gathered feedback on satisfaction from radiologists of varying ranks.MethodsThis prospective IRB approved study included 5600 non-contrast CT scans of the head in various clinical settings, that is, emergency, inpatient, and outpatient units. The patients' risk factors were collected and tested for impacting the performance of DL model utilizing univariate and multivariate regression analyses. The performance of DL model was contrasted to the radiologists' interpretation to determine the presence or absence of ICH with subsequent classification into subcategories of ICH. Key metrics, including accuracy, sensitivity, specificity, positive predictive value, and negative predictive value, were calculated. Receiver operating characteristics curve, along with the area under the curve, were determined. Additionally, a questionnaire was conducted with radiologists of varying ranks to assess their experience with the model.ResultsThe model exhibited outstanding performance, achieving a high sensitivity of 89% and specificity of 96%. Additional performance metrics, including positive predictive value (82%), negative predictive value (97%), and overall accuracy (94%), underscore its robust capabilities. The area under the ROC curve further demonstrated the model's efficacy, reaching 0.954. Multivariate logistic regression revealed statistical significance for age, sex, history of trauma, operative intervention, HTN, and smoking.ConclusionOur study highlights the satisfactory performance of the DL model on a diverse real-world dataset, garnering positive feedback from radiology trainees.

Authors

Institutions

Publication Details

Journal
The Neuroradiology Journal
Published
2024-11-27
DOI
https://doi.org/10.1177/19714009241303078
Citations
5
Primary Topic
Intracerebral and Subarachnoid Hemorrhage Research
Type
article
Field-Weighted Citation Impact
1.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

External validation and performance analysis of a deep learning-based model for the detection of intracranial hemorrhage

Talissa A. Altes, Hossam S. Hassanein, Ayman H. Gaballah, Burak C. Sevim et al.
5 citations
The Neuroradiology Journal
Intracerebral and Subarachnoid Hemorrhage Research
1.85
article

External validation and performance analysis of a deep learning-based model for the detection of intracranial hemorrhage

Talissa A. Altes, Hossam S. Hassanein, Ayman H. Gaballah, Burak C. Sevim, Manal Tantawi, Amna Khan, Ayman Nada, Ali H. Sayed, Mourad Hamouda, Addison Alt
article en
5 citations

Abstract

PurposeWe aimed to investigate the external validation and performance of an FDA-approved deep learning model in labeling intracranial hemorrhage (ICH) cases on a real-world heterogeneous clinical dataset. Furthermore, we delved deeper into evaluating how patients' risk factors influenced the model's performance and gathered feedback on satisfaction from radiologists of varying ranks.MethodsThis prospective IRB approved study included 5600 non-contrast CT scans of the head in various clinical settings, that is, emergency, inpatient, and outpatient units. The patients' risk factors were collected and tested for impacting the performance of DL model utilizing univariate and multivariate regression analyses. The performance of DL model was contrasted to the radiologists' interpretation to determine the presence or absence of ICH with subsequent classification into subcategories of ICH. Key metrics, including accuracy, sensitivity, specificity, positive predictive value, and negative predictive value, were calculated. Receiver operating characteristics curve, along with the area under the curve, were determined. Additionally, a questionnaire was conducted with radiologists of varying ranks to assess their experience with the model.ResultsThe model exhibited outstanding performance, achieving a high sensitivity of 89% and specificity of 96%. Additional performance metrics, including positive predictive value (82%), negative predictive value (97%), and overall accuracy (94%), underscore its robust capabilities. The area under the ROC curve further demonstrated the model's efficacy, reaching 0.954. Multivariate logistic regression revealed statistical significance for age, sex, history of trauma, operative intervention, HTN, and smoking.ConclusionOur study highlights the satisfactory performance of the DL model on a diverse real-world dataset, garnering positive feedback from radiology trainees.

The Neuroradiology JournalVol. 38(3)
Northwell Health (US), The University of Texas MD Anderson Cancer Center (US), Kansas City University (US), St Vincent Hospital (US), Staten Island University Hospital (US), Saint Louis University Hospital (US), Nazareth Hospital (US), University of Pittsburgh Medical Center (US), The University of Texas Medical Branch at Galveston (US), University of Missouri (US)
Good health and well-being
Openalex Percentile: Top 13%
Intracerebral and Subarachnoid Hemorrhage Research
1.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.