Owing to the simultaneous increase in the risk of thrombosis and bleeding in critically ill patients, point-of-care-available diagnostic tests to guide parenteral anticoagulation are warranted. We evaluated the detection of enoxaparin and argatroban, two commonly used parenteral anticoagulants, using the novel ClotPro viscoelastic coagulometer. For this experimental in vitro study at a tertiary care academic center, blood samples were drawn from twelve (six female, six male) healthy volunteers without intake of antithrombotic medication and no history of hemostatic disorders. Blood samples were spiked with enoxaparin (IU.ml<sup>- 1</sup>) and argatroban (µg.ml<sup>- 1</sup>) at increasing concentrations ranging from 0 to 1. The ClotPro Russell's viper venom (RVV)-test and the ClotPro ecarin (ECA)-test clotting time were performed in parallel with conventional coagulation tests (anti-Xa activity, activated partial thromboplastin time, and diluted thrombin time). We observed a strong correlation between anti-Xa activity and the RVV-test clotting time (r = 0.88 (95% confidence interval (CI) 0.8-0.92; p < 0.001)). Although clotting time cutoff values of 71 and 145 s provided high sensitivity and specificity for detecting anti-Xa activity of ≤ 0.1 and ≥0.6 IU.ml<sup>- 1</sup>, we found a poor performance at both high and low concentrations. The ECA-test clotting time revealed a very strong correlation with activated partial thromboplastin time (r = 0.96 (95% CI 0.93-0.97; p < 0.001)) and diluted thrombin time (r = 0.97 (95% CI 0.96-0.98; p < 0.001)). The clotting time cutoff values of 86 and 298-431 s provided high sensitivity and specificity for detecting diluted thrombin time values ≤ 0.1 and 0.5-1 µg.ml<sup>- 1</sup>. Our results suggest that the RVV test is an unreliable method for monitoring enoxaparin treatment, whereas the ECA-test might be an accurate point-of-care alternative for detecting argatroban concentration with potential advantages over standard coagulation tests in terms of point-of-care applicability and turnaround time.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-27
DOI
https://doi.org/10.1038/s41598-024-81396-w
Citations
2
Primary Topic
Heparin-Induced Thrombocytopenia and Thrombosis
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of enoxaparin and argatroban by use of the novel viscoelastic coagulometer ClotPro

Marion Wiegele, Peter Quehenberger, Stefan Ulbing, Stefan Koch et al.
2 citations
Scientific Reports
Heparin-Induced Thrombocytopenia and Thrombosis
1.15
article

Detection of enoxaparin and argatroban by use of the novel viscoelastic coagulometer ClotPro

Marion Wiegele, Peter Quehenberger, Stefan Ulbing, Stefan Koch, Eva Schaden, Johannes Gratz, Christoph Dibiasi, Fabian Schäfer
article en
2 citations

Abstract

Owing to the simultaneous increase in the risk of thrombosis and bleeding in critically ill patients, point-of-care-available diagnostic tests to guide parenteral anticoagulation are warranted. We evaluated the detection of enoxaparin and argatroban, two commonly used parenteral anticoagulants, using the novel ClotPro viscoelastic coagulometer. For this experimental in vitro study at a tertiary care academic center, blood samples were drawn from twelve (six female, six male) healthy volunteers without intake of antithrombotic medication and no history of hemostatic disorders. Blood samples were spiked with enoxaparin (IU.ml<sup>- 1</sup>) and argatroban (µg.ml<sup>- 1</sup>) at increasing concentrations ranging from 0 to 1. The ClotPro Russell's viper venom (RVV)-test and the ClotPro ecarin (ECA)-test clotting time were performed in parallel with conventional coagulation tests (anti-Xa activity, activated partial thromboplastin time, and diluted thrombin time). We observed a strong correlation between anti-Xa activity and the RVV-test clotting time (r = 0.88 (95% confidence interval (CI) 0.8-0.92; p < 0.001)). Although clotting time cutoff values of 71 and 145 s provided high sensitivity and specificity for detecting anti-Xa activity of ≤ 0.1 and ≥0.6 IU.ml<sup>- 1</sup>, we found a poor performance at both high and low concentrations. The ECA-test clotting time revealed a very strong correlation with activated partial thromboplastin time (r = 0.96 (95% CI 0.93-0.97; p < 0.001)) and diluted thrombin time (r = 0.97 (95% CI 0.96-0.98; p < 0.001)). The clotting time cutoff values of 86 and 298-431 s provided high sensitivity and specificity for detecting diluted thrombin time values ≤ 0.1 and 0.5-1 µg.ml<sup>- 1</sup>. Our results suggest that the RVV test is an unreliable method for monitoring enoxaparin treatment, whereas the ECA-test might be an accurate point-of-care alternative for detecting argatroban concentration with potential advantages over standard coagulation tests in terms of point-of-care applicability and turnaround time.

Scientific ReportsVol. 14(1)
Austrian Institute for Health Technology Assessment GmbH (AT), Medical University of Vienna (AT)
Universität Wien, Medizinische Universität Wien
Openalex Percentile: Top 19%
Heparin-Induced Thrombocytopenia and Thrombosis
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.