Efficient Cd separation protocols for high-precision cadmium isotope analyses of diverse samples by double spike MC-ICP-MS

Cadmium isotope analyses are applied for research in planetary, Earth, environmental and life sciences. However, there is still a lack of efficient methods for the separation of the trace element Cd from the different types of samples that are of interest for isotopic analyses. This study presents new and improved Cd separation and purification techniques for meteorite, diverse terrestrial and seawater samples prior to Cd isotope measurements by multiple collector ICP-MS using the double spike approach for mass bias correction. The first separation stage for meteorites and terrestrial samples employs an existing anion exchange chromatography method that uses AG MP-1M resin, whilst AG 1-X8 and Nobias Chelate PA-1 resins were applied for the initial isolation of Cd from small and large seawater samples, respectively. Teflon microcolumns and AG MP-1M anion exchange resin was then employed for further Cd purification of all sample types. The methods consistently isolate Cd from matrix elements more efficiently than previous protocols, whilst achieving consistently high Cd recoveries, of >95 % for meteorite and terrestrial samples and >80 % for seawater samples, combined with low procedural blanks of <0.08 ng. The performance of the new protocols is demonstrated by repeated Cd isotope analyses of well-characterized geological and biological reference materials, which produced data that are in excellent agreement with results that were obtained with previous, more laborious separation methods. Furthermore, precise Cd isotope compositions (δ<sup>114</sup>Cd) are presented for the Murchison meteorite and, for the first time, the ordinary chondrite GRO 95504. Finally, analyses of seven seawater samples, with Cd concentrations between 0.25 and 0.91 nmol kg<sup>-1</sup> using sample volumes of up to 2 L, generated results consistent with those of previous studies. Overall, the new methods thus enable unbiased δ<sup>114</sup>Cd measurements for diverse sample types with a 2SD precision of better than ±0.07 ‰, even for samples with 10 ng or less of natural Cd.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2024-11-27
DOI
https://doi.org/10.1016/j.talanta.2024.127296
Citations
2
Primary Topic
Isotope Analysis in Ecology
Type
article
Field-Weighted Citation Impact
0.92

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient Cd separation protocols for high-precision cadmium isotope analyses of diverse samples by double spike MC-ICP-MS

Zijian Jia, Barry J. Coles, Yihang Huang, Rebekah E. T. Moore et al.
2 citations
Talanta
Isotope Analysis in Ecology
0.92
article

Efficient Cd separation protocols for high-precision cadmium isotope analyses of diverse samples by double spike MC-ICP-MS

Zijian Jia, Barry J. Coles, Yihang Huang, Rebekah E. T. Moore, Mark Rehkämper, Huiyan Xu, Katharina Kreissig
article en
2 citations

Abstract

Cadmium isotope analyses are applied for research in planetary, Earth, environmental and life sciences. However, there is still a lack of efficient methods for the separation of the trace element Cd from the different types of samples that are of interest for isotopic analyses. This study presents new and improved Cd separation and purification techniques for meteorite, diverse terrestrial and seawater samples prior to Cd isotope measurements by multiple collector ICP-MS using the double spike approach for mass bias correction. The first separation stage for meteorites and terrestrial samples employs an existing anion exchange chromatography method that uses AG MP-1M resin, whilst AG 1-X8 and Nobias Chelate PA-1 resins were applied for the initial isolation of Cd from small and large seawater samples, respectively. Teflon microcolumns and AG MP-1M anion exchange resin was then employed for further Cd purification of all sample types. The methods consistently isolate Cd from matrix elements more efficiently than previous protocols, whilst achieving consistently high Cd recoveries, of >95 % for meteorite and terrestrial samples and >80 % for seawater samples, combined with low procedural blanks of <0.08 ng. The performance of the new protocols is demonstrated by repeated Cd isotope analyses of well-characterized geological and biological reference materials, which produced data that are in excellent agreement with results that were obtained with previous, more laborious separation methods. Furthermore, precise Cd isotope compositions (δ<sup>114</sup>Cd) are presented for the Murchison meteorite and, for the first time, the ordinary chondrite GRO 95504. Finally, analyses of seven seawater samples, with Cd concentrations between 0.25 and 0.91 nmol kg<sup>-1</sup> using sample volumes of up to 2 L, generated results consistent with those of previous studies. Overall, the new methods thus enable unbiased δ<sup>114</sup>Cd measurements for diverse sample types with a 2SD precision of better than ±0.07 ‰, even for samples with 10 ng or less of natural Cd.

TalantaVol. 285
Imperial College London (GB)
Science and Technology Facilities Council
Openalex Percentile: Top 21%
Isotope Analysis in Ecology
0.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.