Driving Current and Fault Current Limiting Characteristics of Three-Phase Autotransformer Type SFCL in Power Distributed System Connected with Induction Motor

Generally, in case that the induction motor in power distributed system was driven, larger driving current due to starting operation of induction motor happened, which leads to drop of bus voltage and affects protective relays such as under voltage relay and over current relay. In this paper, to suppress the voltage drop and limit the driving current in power distributed system connected with induction motor, the countermeasure using superconducting fault current limiter (SFCL) was investigated. Among various SFCLs, three-phase autotransformer type SFCL, which was connected with three single-phase autotransformers through symmetrical arrangement of three dual iron-cores, was selected because it had advantage easily to adjust the operational current of SFCL by setting tap. Through the driving tests of induction motor and three-phase ground faults tests in simulated power distribution system, the driving current and fault current limiting operations of three-phase autotransformer type SFCL were analyzed to be performed effectively.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2024-11-28
DOI
https://doi.org/10.5370/kiee.2024.73.11.1917
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Driving Current and Fault Current Limiting Characteristics of Three-Phase Autotransformer Type SFCL in Power Distributed System Connected with Induction Motor

Sung‐Hun Lim, Jun‐Sung Park, Minho Yoon, Seung-Su Choi
The Transactions of The Korean Institute of Electrical Engineers
Power Systems Fault Detection
article

Driving Current and Fault Current Limiting Characteristics of Three-Phase Autotransformer Type SFCL in Power Distributed System Connected with Induction Motor

Sung‐Hun Lim, Jun‐Sung Park, Minho Yoon, Seung-Su Choi
article en

Abstract

Generally, in case that the induction motor in power distributed system was driven, larger driving current due to starting operation of induction motor happened, which leads to drop of bus voltage and affects protective relays such as under voltage relay and over current relay. In this paper, to suppress the voltage drop and limit the driving current in power distributed system connected with induction motor, the countermeasure using superconducting fault current limiter (SFCL) was investigated. Among various SFCLs, three-phase autotransformer type SFCL, which was connected with three single-phase autotransformers through symmetrical arrangement of three dual iron-cores, was selected because it had advantage easily to adjust the operational current of SFCL by setting tap. Through the driving tests of induction motor and three-phase ground faults tests in simulated power distribution system, the driving current and fault current limiting operations of three-phase autotransformer type SFCL were analyzed to be performed effectively.

The Transactions of The Korean Institute of Electrical EngineersVol. 73(11)
Affordable and clean energy
Openalex Percentile: Top 75%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Driving Current and Fault Current Limiting Characteristics of Three-Phase Autotransformer Type SFCL in Power Distributed System Connected with Induction Motor — Sung‐Hun Lim, Jun‐Sung Park, et al. · The Transactions of The Korean Institute of Electrical Engineers (2024) | TGRS Research Map | TGRS