Proposal and Analysis of a DC Superconducting Fault Current Limiting Circuit Breaker with Adjustable CLR

This paper suggests DC superconducting current limiting (SCL) circuit breaker (CB) that consists of two mechanical switchs (SWs), adjustable current limiting reactor (CLR) and two superconducting (SC) elements. The suggested DC SCL-CB can have advantage to perform DC fault current limiting and interrupting operation and two SWs’ sequential opening operation comprising DC SCL-CB by control circuit can protect two SC elements from DC fault current as well. Through DC short-circuit tests, SW₁ was confirmed to alleviates the power burden on SC₁ element and lower turn ratio of adjustable CLR was analyzed to be contributed to fast interrupting operation of SW2 by quench of SC₂ element.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2024-11-28
DOI
https://doi.org/10.5370/kiee.2024.73.11.1924
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposal and Analysis of a DC Superconducting Fault Current Limiting Circuit Breaker with Adjustable CLR

Chan-Muk Park, Su-Hyeon Kim, Sung-Hun Lim
The Transactions of The Korean Institute of Electrical Engineers
HVDC Systems and Fault Protection
article

Proposal and Analysis of a DC Superconducting Fault Current Limiting Circuit Breaker with Adjustable CLR

Chan-Muk Park, Su-Hyeon Kim, Sung-Hun Lim
article en

Abstract

This paper suggests DC superconducting current limiting (SCL) circuit breaker (CB) that consists of two mechanical switchs (SWs), adjustable current limiting reactor (CLR) and two superconducting (SC) elements. The suggested DC SCL-CB can have advantage to perform DC fault current limiting and interrupting operation and two SWs’ sequential opening operation comprising DC SCL-CB by control circuit can protect two SC elements from DC fault current as well. Through DC short-circuit tests, SW₁ was confirmed to alleviates the power burden on SC₁ element and lower turn ratio of adjustable CLR was analyzed to be contributed to fast interrupting operation of SW2 by quench of SC₂ element.

The Transactions of The Korean Institute of Electrical EngineersVol. 73(11)
Climate action
Openalex Percentile: Top 81%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.