A Study on Estimation of Insulation Resistance in Low-Voltage Direct Current Systems Using Open-Type Midpoint Grounding System

In low-voltage DC systems, the grounding system is mainly a two-wire or three-wire IT system. Among them, the IT high-resistance midpoint grounding system has advantages in detecting 1-wire ground fault, but has disadvantages in continuous loss and insulation resistance measurement. This paper proposes a method to estimate the insulation resistance of the + and - lines using the measured voltage when the switch of the high-resistance midpoint is closed/opened in the open-type midpoint grounding system. Through the proposed method, it prevents continuous losses due to high-resistance midpoint grounding and allows the insulation resistance to be estimated through switch control when the measured voltage exceeds a certain value. The proposed method was verified by simulation using MATALB/SIMULINK and experiment.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2024-11-28
DOI
https://doi.org/10.5370/kiee.2024.73.11.2091
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study on Estimation of Insulation Resistance in Low-Voltage Direct Current Systems Using Open-Type Midpoint Grounding System

Jeong-Chay Jeon, Ki-Yeon Lee, Chan-Hyeok Oh, Seung-Taek Lim
The Transactions of The Korean Institute of Electrical Engineers
Engineering Applied Research
article

A Study on Estimation of Insulation Resistance in Low-Voltage Direct Current Systems Using Open-Type Midpoint Grounding System

Jeong-Chay Jeon, Ki-Yeon Lee, Chan-Hyeok Oh, Seung-Taek Lim
article en

Abstract

In low-voltage DC systems, the grounding system is mainly a two-wire or three-wire IT system. Among them, the IT high-resistance midpoint grounding system has advantages in detecting 1-wire ground fault, but has disadvantages in continuous loss and insulation resistance measurement. This paper proposes a method to estimate the insulation resistance of the + and - lines using the measured voltage when the switch of the high-resistance midpoint is closed/opened in the open-type midpoint grounding system. Through the proposed method, it prevents continuous losses due to high-resistance midpoint grounding and allows the insulation resistance to be estimated through switch control when the measured voltage exceeds a certain value. The proposed method was verified by simulation using MATALB/SIMULINK and experiment.

The Transactions of The Korean Institute of Electrical EngineersVol. 73(11)
Affordable and clean energy
Openalex Percentile: Top 76%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Study on Estimation of Insulation Resistance in Low-Voltage Direct Current Systems Using Open-Type Midpoint Grounding System — Jeong-Chay Jeon, Ki-Yeon Lee, et al. · The Transactions of The Korean Institute of Electrical Engineers (2024) | TGRS Research Map | TGRS