Operational Analysis of OCR Due to Application of SFCL in Power Distribution System with Distributed Generations

The application of distributed generations (DGs) is increasing. Because renewable energy is eco-friendly and has low carbon emissions interest on renewable energy based DGs is growing. However, as the number of DGs increases, the fault current magnitude in the system can either increase or decrease during faults. These changes can result in malfunctions or failure of overcurrent relays (OCRs), potentially leading to a large blackout. Research on superconducting fault current limiter (SFCL) to limit fault currents has been conducted, but applying SFCLs in distribution systems with DGs can complicate protective coordination among relays. In this paper, cases of malfunction and failure of OCRs due to the connection of distributed power sources were analyzed, and method to improve the protective coordination of OCRs using SFCLs were proposed.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2024-11-28
DOI
https://doi.org/10.5370/kiee.2024.73.11.1930
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Operational Analysis of OCR Due to Application of SFCL in Power Distribution System with Distributed Generations

Sung‐Hun Lim, Min-Ki Park, Su-Hyeon Kim, Hak-Goon Kim et al.
The Transactions of The Korean Institute of Electrical Engineers
Power Systems and Technologies
article

Operational Analysis of OCR Due to Application of SFCL in Power Distribution System with Distributed Generations

Sung‐Hun Lim, Min-Ki Park, Su-Hyeon Kim, Hak-Goon Kim, Seung-Su Choi
article en

Abstract

The application of distributed generations (DGs) is increasing. Because renewable energy is eco-friendly and has low carbon emissions interest on renewable energy based DGs is growing. However, as the number of DGs increases, the fault current magnitude in the system can either increase or decrease during faults. These changes can result in malfunctions or failure of overcurrent relays (OCRs), potentially leading to a large blackout. Research on superconducting fault current limiter (SFCL) to limit fault currents has been conducted, but applying SFCLs in distribution systems with DGs can complicate protective coordination among relays. In this paper, cases of malfunction and failure of OCRs due to the connection of distributed power sources were analyzed, and method to improve the protective coordination of OCRs using SFCLs were proposed.

The Transactions of The Korean Institute of Electrical EngineersVol. 73(11)
Affordable and clean energy
Openalex Percentile: Top 81%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Operational Analysis of OCR Due to Application of SFCL in Power Distribution System with Distributed Generations — Sung‐Hun Lim, Min-Ki Park, et al. · The Transactions of The Korean Institute of Electrical Engineers (2024) | TGRS Research Map | TGRS