Implementation of a Simulation-Based Digital Twin Model of a Reduced Temperature Control Test Device Using a Reduced Order Model (ROM)

In this study, a simulation-based digital twin model is presented through a reduced temperature control test device test. The simulation of the test device is performed with Fluent from Ansys, a commercial FVM (Finite Volume Method) software. This model consists of RS ROM (Response Surface ROM) that predicts the scalar value HeatEnergy, and Static ROM that predicts the velocity and temperature fields. The experimental verification compares the temperature sensor value with the predicted value of the Static ROM in the design value (DP, Desgin Point) 3. As a result, an average error of about -1.364 [C] occurs.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2024-11-28
DOI
https://doi.org/10.5370/kiee.2024.73.11.1996
Primary Topic
Digital Transformation in Industry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of a Simulation-Based Digital Twin Model of a Reduced Temperature Control Test Device Using a Reduced Order Model (ROM)

M. Baek, Seong-Ju Kim, Minjun Sung, Chang-Seob Kwak
The Transactions of The Korean Institute of Electrical Engineers
Digital Transformation in Industry
article

Implementation of a Simulation-Based Digital Twin Model of a Reduced Temperature Control Test Device Using a Reduced Order Model (ROM)

M. Baek, Seong-Ju Kim, Minjun Sung, Chang-Seob Kwak
article en

Abstract

In this study, a simulation-based digital twin model is presented through a reduced temperature control test device test. The simulation of the test device is performed with Fluent from Ansys, a commercial FVM (Finite Volume Method) software. This model consists of RS ROM (Response Surface ROM) that predicts the scalar value HeatEnergy, and Static ROM that predicts the velocity and temperature fields. The experimental verification compares the temperature sensor value with the predicted value of the Static ROM in the design value (DP, Desgin Point) 3. As a result, an average error of about -1.364 [C] occurs.

The Transactions of The Korean Institute of Electrical EngineersVol. 73(11)
Affordable and clean energy
Openalex Percentile: Top 69%
Digital Transformation in Industry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.