Quality evaluation of ballistocardiogram from fiber optic sensors using fuzzy comprehensive evaluation method

• A novel BCG quality evaluation model based on fuzzy comprehensive evaluation is introduced, integrating four time-domain and frequency-domain indicators. • The proposed BCG quality evaluation model has been validated on micro-bend fiber optic sensors and FBG sensors, demonstrating its accuracy and robustness. • A packaging structure for fiber Bragg grating sensors is proposed, and experimental results demonstrate its effectiveness in capturing BCG signals. Evaluating the quality of ballistocardiogram (BCG) is crucial for enhancing the accuracy of subsequent physiological parameter extraction. The micro-bend fiber optic BCG sensor and fiber Bragg grating BCG sensor are designed and manufactured, and experiments show that they can effectively acquire BCG. A BCG quality evaluation model based on fuzzy comprehensive evaluation is established, which uses four BCG evaluation indicators in time-domain and frequency-domain, including ratio of coefficient of variation, matching degree of J-wave detection, ratio of power spectral density, coefficient of template matching. By analyzing the quality of 800 manually labeled signal samples, the fuzzy membership functions for the four BCG evaluation indicators are determined. Considering the different noise features of various fiber optic sensors, different weight distributions are applied to BCG evaluation indicators for the micro-bend fiber optic BCG sensor and fiber Bragg grating BCG sensor. Applying the quality evaluation model to signals acquired at different times from two types of fiber optic sensors, and classifying them into excellent, average, and poor categories, the accuracy of BCG quality determination for the two types of sensors is 84.50% and 85.25%, respectively.

Authors

Institutions

Publication Details

Journal
Optical Fiber Technology
Published
2024-11-26
DOI
https://doi.org/10.1016/j.yofte.2024.104046
Citations
7
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality evaluation of ballistocardiogram from fiber optic sensors using fuzzy comprehensive evaluation method

Zhiguo Jiang, Beizhan Yan, Jianing Ma, Shuxia Qian et al.
7 citations
Optical Fiber Technology
Non-Invasive Vital Sign Monitoring
1.29
article

Quality evaluation of ballistocardiogram from fiber optic sensors using fuzzy comprehensive evaluation method

Zhiguo Jiang, Beizhan Yan, Jianing Ma, Shuxia Qian, Xianchao Zhang
article en
7 citations

Abstract

• A novel BCG quality evaluation model based on fuzzy comprehensive evaluation is introduced, integrating four time-domain and frequency-domain indicators. • The proposed BCG quality evaluation model has been validated on micro-bend fiber optic sensors and FBG sensors, demonstrating its accuracy and robustness. • A packaging structure for fiber Bragg grating sensors is proposed, and experimental results demonstrate its effectiveness in capturing BCG signals. Evaluating the quality of ballistocardiogram (BCG) is crucial for enhancing the accuracy of subsequent physiological parameter extraction. The micro-bend fiber optic BCG sensor and fiber Bragg grating BCG sensor are designed and manufactured, and experiments show that they can effectively acquire BCG. A BCG quality evaluation model based on fuzzy comprehensive evaluation is established, which uses four BCG evaluation indicators in time-domain and frequency-domain, including ratio of coefficient of variation, matching degree of J-wave detection, ratio of power spectral density, coefficient of template matching. By analyzing the quality of 800 manually labeled signal samples, the fuzzy membership functions for the four BCG evaluation indicators are determined. Considering the different noise features of various fiber optic sensors, different weight distributions are applied to BCG evaluation indicators for the micro-bend fiber optic BCG sensor and fiber Bragg grating BCG sensor. Applying the quality evaluation model to signals acquired at different times from two types of fiber optic sensors, and classifying them into excellent, average, and poor categories, the accuracy of BCG quality determination for the two types of sensors is 84.50% and 85.25%, respectively.

Optical Fiber TechnologyVol. 89
Beijing University of Posts and Telecommunications (CN), Jiaxing University (CN), First Hospital of Jiaxing (CN)
Affordable and clean energy
Openalex Percentile: Top 21%
Non-Invasive Vital Sign Monitoring
1.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.