Application of Multi-Model Adaptive Statistical Iterative Reconstruction-Veo in Ultra-Low Dose Chest CT Examination of Children in Plateau Area.

Objective To explore the application value of multi-model adaptive statistical iterative reconstruction-Veo (ASiR-V) in ultra-low dose chest CT examination of children in the plateau area. Methods The children who underwent chest CT examination in Xizang Autonomous Region People's Hospital were enrolled in this study and assigned into two groups according to the scanning conditions.Group A underwent scanning at a tube voltage of 100 kV and ASiR-V 50% reconstruction,and group B underwent scanning at a tube voltage of 80 kV and ASiR-V 0 (Group B1) and ASiR-V 50% (Group B2) reconstruction.The image quality of each group was evaluated objectively and subjectively.The radiation dose and image quality were compared between groups. Results Groups A and B showed the volume CT dose indexes of (2.33±0.62) mGy and (0.86±0.01) mGy and the dose length products of (65.01±25.12) mGy·cm and (23.55±3.38) mGy·cm,respectively,which presented differences between groups (both <i>P</i><0.001).The image noise in the bilateral upper and middle lung areas in group B2 was lower than that in group B1 but higher than that in group A (all <i>P</i><0.001).There was no significant difference in image quality score of the lung window among groups (all <i>P</i>>0.05).Groups A,B1,and B2 had no significant differences in ascending aorta (<i>P</i>=0.538) or liver CT value (<i>P</i>=0.175) in the mediastinal window.The signal-to-noise ratios and contrast-to-noise ratios of ascending aorta and liver in group B2 were higher than those in group B1 (all <i>P</i><0.001) and lower than those in group A (all <i>P</i><0.05).The image quality score of the mediastinal window followed a descending order of group A>group B2>group B1 (all <i>P</i><0.001)。Conclusion ASiR-V combined with low tube voltage can effectively reduce the radiation dose and guarantee the image quality of chest CT of children in the plateau area.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-02-01
DOI
https://doi.org/10.3881/j.issn.1000-503x.16068
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Multi-Model Adaptive Statistical Iterative Reconstruction-Veo in Ultra-Low Dose Chest CT Examination of Children in Plateau Area.

Rongjie Bai, Cidanwangjiu, Xinxin Wang, Bai-yan Su et al.
PubMed
Medical Imaging Techniques and Applications
article

Application of Multi-Model Adaptive Statistical Iterative Reconstruction-Veo in Ultra-Low Dose Chest CT Examination of Children in Plateau Area.

Rongjie Bai, Cidanwangjiu, Xinxin Wang, Bai-yan Su, Suolangnima, Nimazhuoga
article en

Abstract

Objective To explore the application value of multi-model adaptive statistical iterative reconstruction-Veo (ASiR-V) in ultra-low dose chest CT examination of children in the plateau area. Methods The children who underwent chest CT examination in Xizang Autonomous Region People's Hospital were enrolled in this study and assigned into two groups according to the scanning conditions.Group A underwent scanning at a tube voltage of 100 kV and ASiR-V 50% reconstruction,and group B underwent scanning at a tube voltage of 80 kV and ASiR-V 0 (Group B1) and ASiR-V 50% (Group B2) reconstruction.The image quality of each group was evaluated objectively and subjectively.The radiation dose and image quality were compared between groups. Results Groups A and B showed the volume CT dose indexes of (2.33±0.62) mGy and (0.86±0.01) mGy and the dose length products of (65.01±25.12) mGy·cm and (23.55±3.38) mGy·cm,respectively,which presented differences between groups (both <i>P</i><0.001).The image noise in the bilateral upper and middle lung areas in group B2 was lower than that in group B1 but higher than that in group A (all <i>P</i><0.001).There was no significant difference in image quality score of the lung window among groups (all <i>P</i>>0.05).Groups A,B1,and B2 had no significant differences in ascending aorta (<i>P</i>=0.538) or liver CT value (<i>P</i>=0.175) in the mediastinal window.The signal-to-noise ratios and contrast-to-noise ratios of ascending aorta and liver in group B2 were higher than those in group B1 (all <i>P</i><0.001) and lower than those in group A (all <i>P</i><0.05).The image quality score of the mediastinal window followed a descending order of group A>group B2>group B1 (all <i>P</i><0.001)。Conclusion ASiR-V combined with low tube voltage can effectively reduce the radiation dose and guarantee the image quality of chest CT of children in the plateau area.

PubMedVol. 47(1)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN)
Openalex Percentile: Top 100%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.