B1 inhomogeneity corrected APT MRI based on direct saturation removed omega plot model at 5 T

Motivation: B1 inhomogeneity correction is critical in CEST MRI. Reliable correction methods are desired. Goal(s): This study developed a B1 inhomogeneity correction method based on a direct saturation removed omega plot model and tested its performance in human brain APTw imaging at 5 T. Approach: Four healthy volunteers were scanned under four B1 levels. Corrected signal at nominal B1 was calculated from the omega plot model determined from either two or four B1 levels. Results: B1 inhomogeneity-induced artifact was shown on uncorrected APTw images, which was effectively mitigated after correction. Comparably homogeneous APTw maps were obtained between two and four B1 levels. Impact: The proposed method enables reliable B1 inhomogeneity correction from at least two B1 levels, providing an efficient way to improve quantitative CEST MRI, especially on high-field scanners.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4457
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

B1 inhomogeneity corrected APT MRI based on direct saturation removed omega plot model at 5 T

Hairong Zheng, Dong Liang, Yin Wu, Qiting Wu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

B1 inhomogeneity corrected APT MRI based on direct saturation removed omega plot model at 5 T

Hairong Zheng, Dong Liang, Yin Wu, Qiting Wu, Ye Li
article en

Abstract

Motivation: B1 inhomogeneity correction is critical in CEST MRI. Reliable correction methods are desired. Goal(s): This study developed a B1 inhomogeneity correction method based on a direct saturation removed omega plot model and tested its performance in human brain APTw imaging at 5 T. Approach: Four healthy volunteers were scanned under four B1 levels. Corrected signal at nominal B1 was calculated from the omega plot model determined from either two or four B1 levels. Results: B1 inhomogeneity-induced artifact was shown on uncorrected APTw images, which was effectively mitigated after correction. Comparably homogeneous APTw maps were obtained between two and four B1 levels. Impact: The proposed method enables reliable B1 inhomogeneity correction from at least two B1 levels, providing an efficient way to improve quantitative CEST MRI, especially on high-field scanners.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.