Investigation of Optimal Readout Frequency for the Non-Uniform B0 (NuBo) Field Cycling (FC) Scanner

Motivation: The field cycling (FC) scanner introduces an extra degree of freedom for adjusting the B0 field strength during both polarization and readout. However, the ideal readout Larmor frequency remains unexplored. Goal(s): To investigate the optimal readout Larmor frequency for the non-uniform B0 (NuBo) scanner regarding SNR, T2*, and T2 dephasing. Approach: Controlled experiments at two Larmor frequencies, 1MHz and 2MHz, were conducted. Echo trains at these two frequencies were acquired. Results: Results show that readout at a lower Larmor frequency could benefit from a longer echo train, and longer T2*, but with the penalty of a smaller initial signal amplitude. Impact: This research conducted a comparison of the trade-off between SNR, T2* and T2 decay across various readout Larmor frequencies, potentially offering insights for researchers in the field of field cycling in the future.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2852
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Optimal Readout Frequency for the Non-Uniform B0 (NuBo) Field Cycling (FC) Scanner

Heng Sun, Yonghyun Ha, Chenhao Sun, Gigi Galiana et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Scientific Measurement and Uncertainty Evaluation
article

Investigation of Optimal Readout Frequency for the Non-Uniform B0 (NuBo) Field Cycling (FC) Scanner

Heng Sun, Yonghyun Ha, Chenhao Sun, Gigi Galiana, R. Todd Constable, Anja Samardzija, Ryan Gross
article en

Abstract

Motivation: The field cycling (FC) scanner introduces an extra degree of freedom for adjusting the B0 field strength during both polarization and readout. However, the ideal readout Larmor frequency remains unexplored. Goal(s): To investigate the optimal readout Larmor frequency for the non-uniform B0 (NuBo) scanner regarding SNR, T2*, and T2 dephasing. Approach: Controlled experiments at two Larmor frequencies, 1MHz and 2MHz, were conducted. Echo trains at these two frequencies were acquired. Results: Results show that readout at a lower Larmor frequency could benefit from a longer echo train, and longer T2*, but with the penalty of a smaller initial signal amplitude. Impact: This research conducted a comparison of the trade-off between SNR, T2* and T2 decay across various readout Larmor frequencies, potentially offering insights for researchers in the field of field cycling in the future.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Peace, Justice and strong institutions
Openalex Percentile: Top 79%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.