Impact of RF imperfections on MRF-based and reference B1+ mapping methods with a commercial 1Tx/32Rx head coil

Motivation: Magnetic Resonance Fingerprinting (MRF) and preparation-based reference B1+ mapping approaches yielded an unexpected B1+ offset. Goal(s): Identify the origin of the B1+ offset. Approach: Pick-up coil measurements to evaluate the actual RF pulse shape using a commercial 1Tx/32Rx head-coil at 7T. Results: For the preparation-based B1+ mapping method with rectangular pulses, longer RF rise times (~100 µs) and phase variations (~10°) were observed. Furthermore, during the 21s-long MRF acquisition using sinc-pulses, an increased RF amplitude (~2.5%) was observed. By incorporating the measured RF alterations, the B1+ offset could be substantially reduced. Impact: Unidentified effects of the RF transmission such as deviation in envelope and temporal instability affect measurements. Characterizing the RF transmission enables quantification and correction of these deviations.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0473
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of RF imperfections on MRF-based and reference B1+ mapping methods with a commercial 1Tx/32Rx head coil

Stephan Orzada, Sebastian Schmitter, Berk Silemek, Max Lutz et al.
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Impact of RF imperfections on MRF-based and reference B1+ mapping methods with a commercial 1Tx/32Rx head coil

Stephan Orzada, Sebastian Schmitter, Berk Silemek, Max Lutz, Lance DelaBarre, Christoph Stefan Aigner, Frank Seifert, Tobias Schaeffter
article en

Abstract

Motivation: Magnetic Resonance Fingerprinting (MRF) and preparation-based reference B1+ mapping approaches yielded an unexpected B1+ offset. Goal(s): Identify the origin of the B1+ offset. Approach: Pick-up coil measurements to evaluate the actual RF pulse shape using a commercial 1Tx/32Rx head-coil at 7T. Results: For the preparation-based B1+ mapping method with rectangular pulses, longer RF rise times (~100 µs) and phase variations (~10°) were observed. Furthermore, during the 21s-long MRF acquisition using sinc-pulses, an increased RF amplitude (~2.5%) was observed. By incorporating the measured RF alterations, the B1+ offset could be substantially reduced. Impact: Unidentified effects of the RF transmission such as deviation in envelope and temporal instability affect measurements. Characterizing the RF transmission enables quantification and correction of these deviations.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.