Pulse Sequence Design for Gradient Arrays in MRI

Motivation: Gradient arrays are superior compared to the conventional MR coils. However, there exists no pulse sequence design algorithm for the optimum use of the gradient array. Goal(s): This work proposes a novel pulse sequence design schema for the optimum use of the gradient arraysApproach: The algorithm utilizes a waveform optimization method. This method provides the shortest trapezoidal pulses with three inputs: the area to cover, starting and ending amplitudes. Results: The algorithm is fit for any gradient array weight matrix with an arbitrary number of channels. It can provide the shortest timing values for any imaging plane while preserving the hardware limits. Impact: There exists no pulse sequence design algorithm for the optimum use of the gradient array. We present a novel algorithm fit for any gradient array weighting with an arbitrary number of channels while providing the shortest timing values.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3247
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse Sequence Design for Gradient Arrays in MRI

Reza Babaloo, Mehmet Akif Öztürk, Ergin Atalar
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Ultrasound Imaging and Elastography
article

Pulse Sequence Design for Gradient Arrays in MRI

Reza Babaloo, Mehmet Akif Öztürk, Ergin Atalar
article en

Abstract

Motivation: Gradient arrays are superior compared to the conventional MR coils. However, there exists no pulse sequence design algorithm for the optimum use of the gradient array. Goal(s): This work proposes a novel pulse sequence design schema for the optimum use of the gradient arraysApproach: The algorithm utilizes a waveform optimization method. This method provides the shortest trapezoidal pulses with three inputs: the area to cover, starting and ending amplitudes. Results: The algorithm is fit for any gradient array weight matrix with an arbitrary number of channels. It can provide the shortest timing values for any imaging plane while preserving the hardware limits. Impact: There exists no pulse sequence design algorithm for the optimum use of the gradient array. We present a novel algorithm fit for any gradient array weighting with an arbitrary number of channels while providing the shortest timing values.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.