Accelerated 3D Metabolite T1 Mapping Using Variable-Flip-Angle FID MRSI

Motivation: Metabolite T1 values are needed for T1 correction in short-TR MRSI data. Due to the prolonged scan time, metabolite T1 measurement has been limited to single-voxel or single-slice experiments so far. Goal(s): To develop a novel method for 3D metabolite T1 mapping in a practically feasible scan time. Approach: We used a variable-flip-angle short-TR MRSI to achieve rapid metabolite T1 mapping. The high-dimensional data space was undersampled in a variable-density manner. Associated data processing challenges were solved by generalized-series and low-rank-tensor modelling. Results: Simulation, phantom and healthy subject results demonstrated the feasibility of accelerated 3D metabolite T1 mapping. Impact: The proposed method enables 3D metabolite T1 mapping within a clinically feasible scan time (15 min). This method can be used to correct T1 weighting effects in accelerated short-TR MRSI experiments, producing more quantitative results.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0260
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accelerated 3D Metabolite T1 Mapping Using Variable-Flip-Angle FID MRSI

Bradley P. Sutton, Rong Guo, Zhi‐Pei Liang, Yudu Li et al.
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Accelerated 3D Metabolite T1 Mapping Using Variable-Flip-Angle FID MRSI

Bradley P. Sutton, Rong Guo, Zhi‐Pei Liang, Yudu Li, Jie Luo, Georges El Fakhri, Chao Ma, Yao Li, Jin Wen, Yibo Zhao
article en

Abstract

Motivation: Metabolite T1 values are needed for T1 correction in short-TR MRSI data. Due to the prolonged scan time, metabolite T1 measurement has been limited to single-voxel or single-slice experiments so far. Goal(s): To develop a novel method for 3D metabolite T1 mapping in a practically feasible scan time. Approach: We used a variable-flip-angle short-TR MRSI to achieve rapid metabolite T1 mapping. The high-dimensional data space was undersampled in a variable-density manner. Associated data processing challenges were solved by generalized-series and low-rank-tensor modelling. Results: Simulation, phantom and healthy subject results demonstrated the feasibility of accelerated 3D metabolite T1 mapping. Impact: The proposed method enables 3D metabolite T1 mapping within a clinically feasible scan time (15 min). This method can be used to correct T1 weighting effects in accelerated short-TR MRSI experiments, producing more quantitative results.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accelerated 3D Metabolite T1 Mapping Using Variable-Flip-Angle FID MRSI — Bradley P. Sutton, Rong Guo, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS