Using a Shinnar LeRoux Pulse for 3D Multi Ultra-short TE Look-locker Inversion Recovery for T1-Mapping in the human lungs

Motivation: Lung T1(TE) quantification using 2D UTE was demonstrated as an interesting tool but needs expansion to 3D UTE for better comparability and coverage. However, streaking artefacts originating from the edges of the Field of View are particularly problematic in Lung T1(TE) maps. Goal(s): To reduce streakings in T1(TE) maps caused by B0 inhomogeneities. Approach: A Shinnar LeRoux (SLR) minimum phase pulse was used to limit excitation to a 320mm slab in the Multi Ultra-short TE Look-Locker Inversion Recovery sequence. Results: T1(TE) maps produced using sagittal SLR excitation showed less streakings than using transverse SLR excitation and rectangular pulses, but still had residual streaking. Impact: Inhomogeneity streakings in 3D UTE lung T1(TE) maps were greatly reduced by employing a SLR pulse. With additional efforts during reconstruction, it may be possible to remove the remaining artefacts and quickly acquire parameter maps of the entire lungs.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2917
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using a Shinnar LeRoux Pulse for 3D Multi Ultra-short TE Look-locker Inversion Recovery for T1-Mapping in the human lungs

Mark Oliver Wielpütz, Simon M. F. Triphan, Hans‐Ulrich Kauczor, Ke Zhang
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Atomic and Subatomic Physics Research
article

Using a Shinnar LeRoux Pulse for 3D Multi Ultra-short TE Look-locker Inversion Recovery for T1-Mapping in the human lungs

Mark Oliver Wielpütz, Simon M. F. Triphan, Hans‐Ulrich Kauczor, Ke Zhang
article en

Abstract

Motivation: Lung T1(TE) quantification using 2D UTE was demonstrated as an interesting tool but needs expansion to 3D UTE for better comparability and coverage. However, streaking artefacts originating from the edges of the Field of View are particularly problematic in Lung T1(TE) maps. Goal(s): To reduce streakings in T1(TE) maps caused by B0 inhomogeneities. Approach: A Shinnar LeRoux (SLR) minimum phase pulse was used to limit excitation to a 320mm slab in the Multi Ultra-short TE Look-Locker Inversion Recovery sequence. Results: T1(TE) maps produced using sagittal SLR excitation showed less streakings than using transverse SLR excitation and rectangular pulses, but still had residual streaking. Impact: Inhomogeneity streakings in 3D UTE lung T1(TE) maps were greatly reduced by employing a SLR pulse. With additional efforts during reconstruction, it may be possible to remove the remaining artefacts and quickly acquire parameter maps of the entire lungs.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Sustainable cities and communities
Openalex Percentile: Top 80%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Using a Shinnar LeRoux Pulse for 3D Multi Ultra-short TE Look-locker Inversion Recovery for T1-Mapping in the human lungs — Mark Oliver Wielpütz, Simon M. F. Triphan, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS