Simultaneous acquisition of MR elastography, Dixon and X-ray CT like image

Motivation: The purpose of study was integration of Dixon and X-ray CT like image technique in the GRE-MultiEcho-MRE sequence. Goal(s): The additional visualization of bone damage and water / fat compornents on MR elastography would yield benefits in evaluating radiologic skeletal muscle evaluation, since soft tissue injuries can be assessed directly related to the osseous injuries using one image modality. Approach: The effectiveness of this method was evaluated by volunteer studies using the original MRE pulse sequence and vibration system. Results: This method allows simultaneous acquisition of elastograms, wave images, water/fat component images and X-ray CT like images. Impact: For the patient, a reduction in total imaging time is beneficial. For the clinicians, images such as elastograms, wave images, water/fat component images, and X-ray CT are available simultaneously for multimodal diagnosis.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0560
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous acquisition of MR elastography, Dixon and X-ray CT like image

Yoshito Ishihara, Hisao Nishijo, Koichi Takamoto, Hiroyo Kamio et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Ultrasound Imaging and Elastography
article

Simultaneous acquisition of MR elastography, Dixon and X-ray CT like image

Yoshito Ishihara, Hisao Nishijo, Koichi Takamoto, Hiroyo Kamio, Tomokazu Numano, Daiki Ito, Shota Konuma, Hiromu Oka, Nobuaki Tanabe, J. Kikuchi
article en

Abstract

Motivation: The purpose of study was integration of Dixon and X-ray CT like image technique in the GRE-MultiEcho-MRE sequence. Goal(s): The additional visualization of bone damage and water / fat compornents on MR elastography would yield benefits in evaluating radiologic skeletal muscle evaluation, since soft tissue injuries can be assessed directly related to the osseous injuries using one image modality. Approach: The effectiveness of this method was evaluated by volunteer studies using the original MRE pulse sequence and vibration system. Results: This method allows simultaneous acquisition of elastograms, wave images, water/fat component images and X-ray CT like images. Impact: For the patient, a reduction in total imaging time is beneficial. For the clinicians, images such as elastograms, wave images, water/fat component images, and X-ray CT are available simultaneously for multimodal diagnosis.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 62%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.