Feasibility of High-Resolution SSFSE MR imaging using Deep Learning Reconstruction in Assessment of Ovarian Volume and Follicle Count

Motivation: Transvaginal ultrasonography (TVUS) often underestimates follicle count (FC) compared to MRI. The repeatability of FC and ovarian volume (OV) assessment was still affected by motion artifact on conventional T2-weighted fast spin echo images. Goal(s): To propose a more reliable MRI technique in assessing the FC and OV. Approach: High-resolution single-shot fast spin echo (SSFSE) sequence was used to accelerate the acquisition speed, and AIRTM Recon DL was used to compensate for noise in this study. Results: Contributing to the improved time resolution and reduced noise, SSFSE-DL demonstrated better repeatability in FC and OV assessment compared to the widely used motion-robust PROPELLER technique. Impact: High-resolution SSFSE sequence with DL reconstruction can be a reliable imaging method in the assessment of ovarian morphology. It has a potential in determining the threshold value of FC for PCOM identification in future studies.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2741
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of High-Resolution SSFSE MR imaging using Deep Learning Reconstruction in Assessment of Ovarian Volume and Follicle Count

Yunfei Zha, Yujie Zou, Weiyin Vivian Liu, Wen Zhi et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Feasibility of High-Resolution SSFSE MR imaging using Deep Learning Reconstruction in Assessment of Ovarian Volume and Follicle Count

Yunfei Zha, Yujie Zou, Weiyin Vivian Liu, Wen Zhi, Liang Li, Renjie Yang
article en

Abstract

Motivation: Transvaginal ultrasonography (TVUS) often underestimates follicle count (FC) compared to MRI. The repeatability of FC and ovarian volume (OV) assessment was still affected by motion artifact on conventional T2-weighted fast spin echo images. Goal(s): To propose a more reliable MRI technique in assessing the FC and OV. Approach: High-resolution single-shot fast spin echo (SSFSE) sequence was used to accelerate the acquisition speed, and AIRTM Recon DL was used to compensate for noise in this study. Results: Contributing to the improved time resolution and reduced noise, SSFSE-DL demonstrated better repeatability in FC and OV assessment compared to the widely used motion-robust PROPELLER technique. Impact: High-resolution SSFSE sequence with DL reconstruction can be a reliable imaging method in the assessment of ovarian morphology. It has a potential in determining the threshold value of FC for PCOM identification in future studies.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.