Practical sampling strategies for volumetric cardiac real-time MRI using stack-of-spirals at 0.55T

Motivation: Volumetric real-time MRI is desirable to accurately characterize beat-to-beat cardiac function in patients with arrythmia or heart failure. Goal(s): To identify practical data sampling strategies for volumetric real-time MRI and evaluate cardiac volume measurements against gated reference scans. Approach: We focus on stack-of-spirals bSSFP at 0.55T. We use simulations and in-vivo experiments to compare three sampling strategies that minimize eddy currents. Results: A Gaussian distribution of the stack-of-spirals was found to provide the best real-time image quality and most accurate LV volumes, with under-estimation of end-diastolic volume by 7.44% and over-estimation of end-systolic volume by 18.33%. Impact: Beat-to-beat cardiac function is important to measure in the context of arrhythmia, cardiac stress testing and in interventional MRI, where real-time volumetric coverage will facilitate assessment and monitoring of cardiac function.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3237
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practical sampling strategies for volumetric cardiac real-time MRI using stack-of-spirals at 0.55T

Prakash Kumar, Rajiv Ramasawmy, Krishna S. Nayak, Ahsan Javed et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Practical sampling strategies for volumetric cardiac real-time MRI using stack-of-spirals at 0.55T

Prakash Kumar, Rajiv Ramasawmy, Krishna S. Nayak, Ahsan Javed, Adrienne E. Campbell‐Washburn, Ye Tian
article en

Abstract

Motivation: Volumetric real-time MRI is desirable to accurately characterize beat-to-beat cardiac function in patients with arrythmia or heart failure. Goal(s): To identify practical data sampling strategies for volumetric real-time MRI and evaluate cardiac volume measurements against gated reference scans. Approach: We focus on stack-of-spirals bSSFP at 0.55T. We use simulations and in-vivo experiments to compare three sampling strategies that minimize eddy currents. Results: A Gaussian distribution of the stack-of-spirals was found to provide the best real-time image quality and most accurate LV volumes, with under-estimation of end-diastolic volume by 7.44% and over-estimation of end-systolic volume by 18.33%. Impact: Beat-to-beat cardiac function is important to measure in the context of arrhythmia, cardiac stress testing and in interventional MRI, where real-time volumetric coverage will facilitate assessment and monitoring of cardiac function.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 62%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.