Experimental Investigation of Interfering Factors in Cardiac Sensing of Beat Pilot Tone

Motivation: Beat Pilot Tone (BPT) has been proposed as a non-contact and accurate cardiac sensing method seamlessly integrated with MR systems. However, BPT is sensitive to interference, thereby limiting its ability to robustly obtain fine-grained cardiac waveform. Goal(s): Our goal was to demonstrate main factors that could lead to corrupted BPT signal. Approach: We conducted a series of comparative experiments on the hypothesized influencing factors. Results: The experiments suggested that BPT transmit power, imaging orientation and other physiological motion like respiration caused varying degradation to the BPT signal. Impact: The demonstration of interfering factors of BPT cardiac sensing could guide the correct BPT setup and interference suppression method design. This helps BPT to robustly obtain fine-grained cardiac waveform, which could be used for MR motion correction and clinical diagnosis.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3914
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation of Interfering Factors in Cardiac Sensing of Beat Pilot Tone

Suen Chen, Hao-Yu Sun, Wei Hou, Qichen Ding et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Non-Invasive Vital Sign Monitoring
article

Experimental Investigation of Interfering Factors in Cardiac Sensing of Beat Pilot Tone

Suen Chen, Hao-Yu Sun, Wei Hou, Qichen Ding, Zhiyong Zhang, Hao Chen, Sijie Zhong
article en

Abstract

Motivation: Beat Pilot Tone (BPT) has been proposed as a non-contact and accurate cardiac sensing method seamlessly integrated with MR systems. However, BPT is sensitive to interference, thereby limiting its ability to robustly obtain fine-grained cardiac waveform. Goal(s): Our goal was to demonstrate main factors that could lead to corrupted BPT signal. Approach: We conducted a series of comparative experiments on the hypothesized influencing factors. Results: The experiments suggested that BPT transmit power, imaging orientation and other physiological motion like respiration caused varying degradation to the BPT signal. Impact: The demonstration of interfering factors of BPT cardiac sensing could guide the correct BPT setup and interference suppression method design. This helps BPT to robustly obtain fine-grained cardiac waveform, which could be used for MR motion correction and clinical diagnosis.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Life below water
Openalex Percentile: Top 80%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.