Comparison of Renal ASL Signal-to-noise Ratio and Corticomedullary Contrast between 3T and 5T MRI

Motivation: As the most promising method for measuring tissue perfusion, ASL suffers from low signal-to-noise ratio (SNR), with tagged blood typically causing only few percent of signal difference. Goal(s): Explore if the use of 5T MRI could lead to higher SNR and CNR for renal ASL than 3T. Approach: We performed FAIR-EPI on the kidneys of three healthy subjects at 6 inversion times on both 3T and 5T systems. SNR and CNR of difference images were calculated and compared. Results: SNR at 5T was 10.72±2.81, higher than 7.75±2.65 (P = 0.008) at 3T, and CNR were 9.08±4.08 and 6.53±2.14 (P=0.029), respectively. Impact: 5T ASL provides difference images with higher SNR and CNR to allow faster acquisition and better corticomedullary differentiation while maintaining comparable image quality.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0474
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Renal ASL Signal-to-noise Ratio and Corticomedullary Contrast between 3T and 5T MRI

Xiangwei Kong, Mingyan Wu, Xinzhen Zhang, Xinyue Jiang et al.
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Comparison of Renal ASL Signal-to-noise Ratio and Corticomedullary Contrast between 3T and 5T MRI

Xiangwei Kong, Mingyan Wu, Xinzhen Zhang, Xinyue Jiang, Yanbin Li, Jeff Zhang, Chen Chen
article en

Abstract

Motivation: As the most promising method for measuring tissue perfusion, ASL suffers from low signal-to-noise ratio (SNR), with tagged blood typically causing only few percent of signal difference. Goal(s): Explore if the use of 5T MRI could lead to higher SNR and CNR for renal ASL than 3T. Approach: We performed FAIR-EPI on the kidneys of three healthy subjects at 6 inversion times on both 3T and 5T systems. SNR and CNR of difference images were calculated and compared. Results: SNR at 5T was 10.72±2.81, higher than 7.75±2.65 (P = 0.008) at 3T, and CNR were 9.08±4.08 and 6.53±2.14 (P=0.029), respectively. Impact: 5T ASL provides difference images with higher SNR and CNR to allow faster acquisition and better corticomedullary differentiation while maintaining comparable image quality.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Good health and well-being
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of Renal ASL Signal-to-noise Ratio and Corticomedullary Contrast between 3T and 5T MRI — Xiangwei Kong, Mingyan Wu, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS