Test-retest reliability of myelin volume fraction quantified with multicomponent MPnRAGE

Motivation: There is a need for rapid and high-resolution myelin water imaging techniques, while high test-retest reliability is necessary for widespread adoption. Goal(s): Evaluate the repeatability of multicomponent relaxometry with MPnRAGE. Approach: Data from 12 adolescent subjects scanned 3 consecutive times were reconstructed with motion-correction and fit to multicomponent MPnRAGE model. Coefficient of variation (CoV) was calculated across the 3 scans for each subject for several white and gray matter regions. Results: Mean CoV was <7% across white matter regions. Myelin volume fraction trends between regions were also consistent with prior T2-based techniques. Impact: A recently developed T1-based technique for myelin water imaging with MPnRAGE demonstrates high repeatability across consecutive scans. Multicomponent relaxometry with MPnRAGE enables high-resolution and motion-corrected myelin mapping in under 10 minutes of scan time.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3712
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test-retest reliability of myelin volume fraction quantified with multicomponent MPnRAGE

Steven Kecskemeti, Douglas Dean, José Guerrero-González, J. A. Weaver
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Test-retest reliability of myelin volume fraction quantified with multicomponent MPnRAGE

Steven Kecskemeti, Douglas Dean, José Guerrero-González, J. A. Weaver
article en

Abstract

Motivation: There is a need for rapid and high-resolution myelin water imaging techniques, while high test-retest reliability is necessary for widespread adoption. Goal(s): Evaluate the repeatability of multicomponent relaxometry with MPnRAGE. Approach: Data from 12 adolescent subjects scanned 3 consecutive times were reconstructed with motion-correction and fit to multicomponent MPnRAGE model. Coefficient of variation (CoV) was calculated across the 3 scans for each subject for several white and gray matter regions. Results: Mean CoV was <7% across white matter regions. Myelin volume fraction trends between regions were also consistent with prior T2-based techniques. Impact: A recently developed T1-based technique for myelin water imaging with MPnRAGE demonstrates high repeatability across consecutive scans. Multicomponent relaxometry with MPnRAGE enables high-resolution and motion-corrected myelin mapping in under 10 minutes of scan time.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Test-retest reliability of myelin volume fraction quantified with multicomponent MPnRAGE — Steven Kecskemeti, Douglas Dean, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS