Design of a segmented RF shield to minimize eddy currents on low-field Halbach MRI systems

Motivation: Eddy-currents induced in the shielding layer placed between the gradient coils and RF transmit coil can create artefacts and lead to longer echo times. Reducing these currents by segmenting the shield while keeping the noise-reduction properties is important for low-field point-of-care systems. Goal(s): Minimizing eddy currents for transverse B0 magnets while maintaining shielding effectiveness. Approach: The segmentation locations are chosen by taking into account the wire pattern of the RF coil and gradient-induced eddy current simulations. Results: The suggested shield results in a decrease in the measured eddy current effects by a factor of 15, with only a noise increase of 4%. Impact: The proposed shield reduces eddy current effects by a factor of 15, giving the opportunity to achieve shorter echo-times and higher slew rates with fewer distortions on point-of-care low-field systems.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4078
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a segmented RF shield to minimize eddy currents on low-field Halbach MRI systems

Rob Remis, Bart de Vos, Thomas O’Reilly, Andrew Webb
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Design of a segmented RF shield to minimize eddy currents on low-field Halbach MRI systems

Rob Remis, Bart de Vos, Thomas O’Reilly, Andrew Webb
article en

Abstract

Motivation: Eddy-currents induced in the shielding layer placed between the gradient coils and RF transmit coil can create artefacts and lead to longer echo times. Reducing these currents by segmenting the shield while keeping the noise-reduction properties is important for low-field point-of-care systems. Goal(s): Minimizing eddy currents for transverse B0 magnets while maintaining shielding effectiveness. Approach: The segmentation locations are chosen by taking into account the wire pattern of the RF coil and gradient-induced eddy current simulations. Results: The suggested shield results in a decrease in the measured eddy current effects by a factor of 15, with only a noise increase of 4%. Impact: The proposed shield reduces eddy current effects by a factor of 15, giving the opportunity to achieve shorter echo-times and higher slew rates with fewer distortions on point-of-care low-field systems.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.