Principal Component Analysis Reconstruction Improves Visualization of Multivolume MR Spectroscopic Imaging at 1.5 T

Motivation: We address the critical problem of the low signal-to-noise ratio (SNR) of in vivo MR spectroscopic imaging (MRSI) at 1.5 tesla using principal component analysis (PCA). Goal(s): We seek to improve the translatability of MRSI acquired in 1.5T clinical scanners by improving data visualization using PCA reconstruction (PCAR). Approach: We initially corrected for spectral phase and frequency variations in multivolume 31P and 1H MRSI data noninvasively acquired at 1.5 T from human subjects and subsequently used PCAR. Results: We validate the improvement of the MRSI data after PCAR by demonstrating signals that were not distinguishable in the original datasets. Impact: Principal component analysis reconstruction (PCAR) improves the accuracy to assess spectral signals from multivolume 31P and 1H MR spectroscopic imaging data acquired on highly accessible 1.5T clinical scanners, increasing their potential to become noninvasive metabolic biomarkers of human diseases.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4682
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Principal Component Analysis Reconstruction Improves Visualization of Multivolume MR Spectroscopic Imaging at 1.5 T

Fernando Arias‐Mendoza, R. Srinivasan, Kavindra Nath, Lin Li
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Principal Component Analysis Reconstruction Improves Visualization of Multivolume MR Spectroscopic Imaging at 1.5 T

Fernando Arias‐Mendoza, R. Srinivasan, Kavindra Nath, Lin Li
article en

Abstract

Motivation: We address the critical problem of the low signal-to-noise ratio (SNR) of in vivo MR spectroscopic imaging (MRSI) at 1.5 tesla using principal component analysis (PCA). Goal(s): We seek to improve the translatability of MRSI acquired in 1.5T clinical scanners by improving data visualization using PCA reconstruction (PCAR). Approach: We initially corrected for spectral phase and frequency variations in multivolume 31P and 1H MRSI data noninvasively acquired at 1.5 T from human subjects and subsequently used PCAR. Results: We validate the improvement of the MRSI data after PCAR by demonstrating signals that were not distinguishable in the original datasets. Impact: Principal component analysis reconstruction (PCAR) improves the accuracy to assess spectral signals from multivolume 31P and 1H MR spectroscopic imaging data acquired on highly accessible 1.5T clinical scanners, increasing their potential to become noninvasive metabolic biomarkers of human diseases.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.