Two-pulse phase-modulated (TPPM) 1H decoupling for detection of the C1-glycogen peak in 13C MRS using a 3T clinical scanner.

Motivation: To develop a safe MR method to non-invasively measure skeletal muscle glycogen levels in humans. Goal(s): To reduce SAR without degrading the spectral quality of the 1H-decoupled C1-glycogen peak in 13C MRS. Approach: To introduce the two-pulse phase-modulated (TPPM) 1H decoupling scheme, which is widely used for 13C NMR of organic solids, into the 13C MRS pulse sequence for a clinical scanner. Results: The 1H-decoupled C1-glycogen peak could be obtained from a solution phantom using a clinical 3T scanner while reducing SAR with shortening the duration of the TPPM 1H decoupling during 13C FID acquisition. Impact: 13C MRS with the TPPM 1H decoupling for measuring human skeletal muscle glycogen levels may be more advantageous at high magnetic fields due to the lower SAR, leading to higher SNR or shorter scan times.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3029
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-pulse phase-modulated (TPPM) 1H decoupling for detection of the C1-glycogen peak in 13C MRS using a 3T clinical scanner.

Hideto Kuribayashi, Toshiro Inubushi
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Two-pulse phase-modulated (TPPM) 1H decoupling for detection of the C1-glycogen peak in 13C MRS using a 3T clinical scanner.

Hideto Kuribayashi, Toshiro Inubushi
article en

Abstract

Motivation: To develop a safe MR method to non-invasively measure skeletal muscle glycogen levels in humans. Goal(s): To reduce SAR without degrading the spectral quality of the 1H-decoupled C1-glycogen peak in 13C MRS. Approach: To introduce the two-pulse phase-modulated (TPPM) 1H decoupling scheme, which is widely used for 13C NMR of organic solids, into the 13C MRS pulse sequence for a clinical scanner. Results: The 1H-decoupled C1-glycogen peak could be obtained from a solution phantom using a clinical 3T scanner while reducing SAR with shortening the duration of the TPPM 1H decoupling during 13C FID acquisition. Impact: 13C MRS with the TPPM 1H decoupling for measuring human skeletal muscle glycogen levels may be more advantageous at high magnetic fields due to the lower SAR, leading to higher SNR or shorter scan times.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.