Spiral T1w-Dixon-VIBE for high resolution abdominal imaging at 0.55T

Motivation: Breath-held abdominal fat-suppressed imaging is challenging at mid- and low-field strengths (<1.5T). Fat saturation often fails due to the short T1 of lipid; and Cartesian Dixon imaging provides poor spatial resolution due to the need for long ∆TE, due to the smaller ∆f between water and lipid. Goal(s): Breath-held fat-suppressed high-resolution volumetric abdominal imaging with T1 contrast. Approach: Stack-of-Spirals Dixon imaging, with estimation and compensation for phase due to concomitant fields Results: We demonstrate that spiral Dixon imaging at 0.55T makes excellent use of the required ∆TE, improving SNR efficiency and spatial resolution (1.7x1.7x5.0mm3) compared Cartesian Dixon (3.5x3.5x5.0mm3), within a 17-second breath-hold. Impact: We demonstrate that spiral Dixon single breath-hold volumetric imaging is an attractive alternative to existing Cartesian-based methods for volumetric single breath-hold fat-suppressed imaging at 0.55T, as it simultaneously provides high-resolution and excellent fat-suppression.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0425
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spiral T1w-Dixon-VIBE for high resolution abdominal imaging at 0.55T

Bilal Taşdelen, Sophia Cui, Krishna S. Nayak, Nam Lee
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Spiral T1w-Dixon-VIBE for high resolution abdominal imaging at 0.55T

Bilal Taşdelen, Sophia Cui, Krishna S. Nayak, Nam Lee
article en

Abstract

Motivation: Breath-held abdominal fat-suppressed imaging is challenging at mid- and low-field strengths (<1.5T). Fat saturation often fails due to the short T1 of lipid; and Cartesian Dixon imaging provides poor spatial resolution due to the need for long ∆TE, due to the smaller ∆f between water and lipid. Goal(s): Breath-held fat-suppressed high-resolution volumetric abdominal imaging with T1 contrast. Approach: Stack-of-Spirals Dixon imaging, with estimation and compensation for phase due to concomitant fields Results: We demonstrate that spiral Dixon imaging at 0.55T makes excellent use of the required ∆TE, improving SNR efficiency and spatial resolution (1.7x1.7x5.0mm3) compared Cartesian Dixon (3.5x3.5x5.0mm3), within a 17-second breath-hold. Impact: We demonstrate that spiral Dixon single breath-hold volumetric imaging is an attractive alternative to existing Cartesian-based methods for volumetric single breath-hold fat-suppressed imaging at 0.55T, as it simultaneously provides high-resolution and excellent fat-suppression.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.