Transformer-Based Automatic Pipeline for 3D Needle Localization on Intra-Procedural 3D MRI

Motivation: Needle localization on 3D magnetic resonance imaging (MRI) is critical for MRI-guided percutaneous interventions, but current manual methods are time-consuming. Goal(s): To develop a transformer-based pipeline for accurate and rapid automatic 3D needle localization on intra-procedural 3D MRI. Approach: The proposed pipeline adopted a coarse-to-fine segmentation strategy by combining 3D and 2D shifted window (Swin) Transformer networks. The performance was evaluated in pre-clinical pig datasets and compared with human-annotated references. Results: Computation time was 6 sec/volume. The median 3D needle tip and axis localization errors were 1.48 mm (1.09 pixels) and 0.98°, which were comparable to human-level accuracy. Impact: The automatic transformer-based pipeline developed in this work achieved rapid (~6s) and accurate pixel-level 3D needle localization on intra-procedural 3D MRI. This new pipeline has the potential to improve MRI-guided percutaneous interventions.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0455
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transformer-Based Automatic Pipeline for 3D Needle Localization on Intra-Procedural 3D MRI

Fatemeh Zabihollahy, Wenqi Zhou, Holden H. Wu, David Lu et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Anatomy and Medical Technology
article

Transformer-Based Automatic Pipeline for 3D Needle Localization on Intra-Procedural 3D MRI

Fatemeh Zabihollahy, Wenqi Zhou, Holden H. Wu, David Lu, Xin-Zhou Li
article en

Abstract

Motivation: Needle localization on 3D magnetic resonance imaging (MRI) is critical for MRI-guided percutaneous interventions, but current manual methods are time-consuming. Goal(s): To develop a transformer-based pipeline for accurate and rapid automatic 3D needle localization on intra-procedural 3D MRI. Approach: The proposed pipeline adopted a coarse-to-fine segmentation strategy by combining 3D and 2D shifted window (Swin) Transformer networks. The performance was evaluated in pre-clinical pig datasets and compared with human-annotated references. Results: Computation time was 6 sec/volume. The median 3D needle tip and axis localization errors were 1.48 mm (1.09 pixels) and 0.98°, which were comparable to human-level accuracy. Impact: The automatic transformer-based pipeline developed in this work achieved rapid (~6s) and accurate pixel-level 3D needle localization on intra-procedural 3D MRI. This new pipeline has the potential to improve MRI-guided percutaneous interventions.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 80%
Anatomy and Medical Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.