Trade-off between Readout Duration and Concomitant Field Effect in 3D MRF at 0.55T

Motivation: The use of long readouts in 3D MRF improves SNR efficiency but also suffers from stronger concomitant field effects. Goal(s): To evaluate the trade-off between readout duration and concomitant field effects in 0.55T 3D MRF and evaluate mitigation using the MaxGIRF framework. Approach: We performed 0.55T 3D MRF scans of 14 readout durations on the NIST/ISMRM phantom and compared reconstructions with and without concomitant field effects compensation. We analyzed T1 array's standard deviations as a function of readout duration. Results: With correction, MRF T1 standard deviation reduced to stability due to improved SNR efficiency of long readouts, however, broke due to uncorrectable blurring. Impact: Practical trade-off between a readout duration and concomitant field effects are demonstrated. 0.55T 3D MRF benefits from a longer readout duration (6.1-14.7ms) provided a concomitant field effect correction.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3574
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trade-off between Readout Duration and Concomitant Field Effect in 3D MRF at 0.55T

Krishna S. Nayak, Zhibo Zhu, Nam Lee
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Trade-off between Readout Duration and Concomitant Field Effect in 3D MRF at 0.55T

Krishna S. Nayak, Zhibo Zhu, Nam Lee
article en

Abstract

Motivation: The use of long readouts in 3D MRF improves SNR efficiency but also suffers from stronger concomitant field effects. Goal(s): To evaluate the trade-off between readout duration and concomitant field effects in 0.55T 3D MRF and evaluate mitigation using the MaxGIRF framework. Approach: We performed 0.55T 3D MRF scans of 14 readout durations on the NIST/ISMRM phantom and compared reconstructions with and without concomitant field effects compensation. We analyzed T1 array's standard deviations as a function of readout duration. Results: With correction, MRF T1 standard deviation reduced to stability due to improved SNR efficiency of long readouts, however, broke due to uncorrectable blurring. Impact: Practical trade-off between a readout duration and concomitant field effects are demonstrated. 0.55T 3D MRF benefits from a longer readout duration (6.1-14.7ms) provided a concomitant field effect correction.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Trade-off between Readout Duration and Concomitant Field Effect in 3D MRF at 0.55T — Krishna S. Nayak, Zhibo Zhu, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS