A comparison of semi-automatic quality control methods for 3D-T1 weighted scans

Motivation: The implementation of QC in T1w MRI scans remains unstandardized and still involves human specialists, without consensus on a systematic approach to identify the presence of artifactsGoal(s): Our goal was to compare the relative performance of three algorithms with visual QC, and compare their capabilities in detecting simulated blurring, ghosting, and noise artifacts on a new unseen dataset. Approach: Synthetic artifacts were introduced into MRI scans that passed visual quality control, and thresholds were determined for CAT12 and LONIQC, and a classifier for MRIQC was trained. Results: MRIQC outperformed CAT12 and LONIQC in detecting both real artifacts as well as simulated artifacts. Impact: Substantial differences in the performance of different automatic quality control algorithms were shown when compared to visual QC and on simulated data. This suggests that better evaluation of the relation between artifact type, input features and classification methods is needed.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3017
Primary Topic
Industrial Vision Systems and Defect Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparison of semi-automatic quality control methods for 3D-T1 weighted scans

Anouk Schrantee, Henk J. M. M. Mutsaerts, Óscar Peña‐Nogales, Frederik Barkhof et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Industrial Vision Systems and Defect Detection
article

A comparison of semi-automatic quality control methods for 3D-T1 weighted scans

Anouk Schrantee, Henk J. M. M. Mutsaerts, Óscar Peña‐Nogales, Frederik Barkhof, Janine Hendriks, Richard Joules, Robin Wolz, Paulo Rodrigez
article en

Abstract

Motivation: The implementation of QC in T1w MRI scans remains unstandardized and still involves human specialists, without consensus on a systematic approach to identify the presence of artifactsGoal(s): Our goal was to compare the relative performance of three algorithms with visual QC, and compare their capabilities in detecting simulated blurring, ghosting, and noise artifacts on a new unseen dataset. Approach: Synthetic artifacts were introduced into MRI scans that passed visual quality control, and thresholds were determined for CAT12 and LONIQC, and a classifier for MRIQC was trained. Results: MRIQC outperformed CAT12 and LONIQC in detecting both real artifacts as well as simulated artifacts. Impact: Substantial differences in the performance of different automatic quality control algorithms were shown when compared to visual QC and on simulated data. This suggests that better evaluation of the relation between artifact type, input features and classification methods is needed.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 69%
Industrial Vision Systems and Defect Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.