Phase jolt: Second spatial derivative of phase images is a new contrast that offers many benefits for SWI type processing

Motivation: Unlike magnitude images, even simple averaging is difficult with phase images, because of the circular nature of phase, spanning 2pi radians range. Goal(s): In our research that uses mesoscopic imaging (< 0.5 mm isotropic) at 7 T, we need to average multiple acquisitions to increase SNR. Being unable to average straightforwardly together with the lack of natural zero point is a critical constraint. Approach: To address this problem, we propose to operate on the magnitude of the second spatial derivative of phase images - called “phase jolt”. Results: Our results show phase jolt offers benefits for processing associated with SWI imaging. Impact: Phase jolt is an easy to implement new contrast where vessels and non brain tissue are highlighted and background bias field is mitigated. Therefore, phase jolt images have potential to be impactful in any setting where phase images are used.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/1070
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase jolt: Second spatial derivative of phase images is a new contrast that offers many benefits for SWI type processing

Saskia Bollmann, Rainer Goebel, Desmond H. Y. Tse, Ömer Faruk Gülban et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Optical measurement and interference techniques
article

Phase jolt: Second spatial derivative of phase images is a new contrast that offers many benefits for SWI type processing

Saskia Bollmann, Rainer Goebel, Desmond H. Y. Tse, Ömer Faruk Gülban, Kendrick Kay, Laurentius Huber, Andreas Deistung, Dimo Ivanov
article en

Abstract

Motivation: Unlike magnitude images, even simple averaging is difficult with phase images, because of the circular nature of phase, spanning 2pi radians range. Goal(s): In our research that uses mesoscopic imaging (< 0.5 mm isotropic) at 7 T, we need to average multiple acquisitions to increase SNR. Being unable to average straightforwardly together with the lack of natural zero point is a critical constraint. Approach: To address this problem, we propose to operate on the magnitude of the second spatial derivative of phase images - called “phase jolt”. Results: Our results show phase jolt offers benefits for processing associated with SWI imaging. Impact: Phase jolt is an easy to implement new contrast where vessels and non brain tissue are highlighted and background bias field is mitigated. Therefore, phase jolt images have potential to be impactful in any setting where phase images are used.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 79%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.