Tsunami Debris Damming Forces and Associated Coefficients for Elevated Coastal Structure Columns: Experimental Comparison to ASCE 7-22 Minimum Design Loads

Debris damming forces of 1∶20-scale shipping containers freely accumulated against elevated coastal structure columns were experimentally determined to evaluate ASCE 7-22 tsunami-resilient design standards. Three inundation conditions were generated to represent Froude regimes estimated in posttsunami field studies. Three different column array densities and two different shipping container sizes were evaluated. A photogrammetric method was employed to estimate the submerged projected area of in situ transient debris dams from two synchronized camera perspectives. Relative to this experimental data, it was found that the ASCE 7-22 equation for simplified equivalent uniform lateral static pressure is conservative by a mean factor of safety of 14.6 and performs as intended given the prescribed scope. Similarly, the ASCE 7-22 equation for detailed hydrodynamic lateral forces yielded a lower mean factor of safety of 2.4 but maintained design conservatism across all tested experimental conditions, also performing as intended. Minimum closure ratios and overall structure drag coefficients serve as input values for these detailed hydrodynamic lateral design loads. The proportion of closure coefficients prescribed by ASCE 7-22 tend to be reasonably conservative in general, and any instances of experimental exceedance of these design values did not appear to affect the design conservatism of Eq. (3). Finally, drag coefficients for rectilinear structures prescribed by ASCE 7-22 appear unrepresentative of coastal structures, which tend to generate column-flow interactions and unbalanced hydrostatic conditions. It is therefore suggested that the flow resistance of such structures be quantified via a bulk resistance coefficient, indicated by recent literature as a more appropriate measure applicable to surface-piercing flow obstructions.

Authors

Institutions

Publication Details

Journal
Journal of Structural Engineering
Published
2024-11-26
DOI
https://doi.org/10.1061/jsendh.steng-13763
Citations
2
Primary Topic
Earthquake and Tsunami Effects
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tsunami Debris Damming Forces and Associated Coefficients for Elevated Coastal Structure Columns: Experimental Comparison to ASCE 7-22 Minimum Design Loads

Daniel T. Cox, Hyoungsu Park, Ravindu Jayasekara, Pedro Lomónaco et al.
2 citations
Journal of Structural Engineering
Earthquake and Tsunami Effects
0.52
article

Tsunami Debris Damming Forces and Associated Coefficients for Elevated Coastal Structure Columns: Experimental Comparison to ASCE 7-22 Minimum Design Loads

Daniel T. Cox, Hyoungsu Park, Ravindu Jayasekara, Pedro Lomónaco, Myung Jin Koh, Sabarethinam Kameshwar, Kellen Doyle
article en
2 citations

Abstract

Debris damming forces of 1∶20-scale shipping containers freely accumulated against elevated coastal structure columns were experimentally determined to evaluate ASCE 7-22 tsunami-resilient design standards. Three inundation conditions were generated to represent Froude regimes estimated in posttsunami field studies. Three different column array densities and two different shipping container sizes were evaluated. A photogrammetric method was employed to estimate the submerged projected area of in situ transient debris dams from two synchronized camera perspectives. Relative to this experimental data, it was found that the ASCE 7-22 equation for simplified equivalent uniform lateral static pressure is conservative by a mean factor of safety of 14.6 and performs as intended given the prescribed scope. Similarly, the ASCE 7-22 equation for detailed hydrodynamic lateral forces yielded a lower mean factor of safety of 2.4 but maintained design conservatism across all tested experimental conditions, also performing as intended. Minimum closure ratios and overall structure drag coefficients serve as input values for these detailed hydrodynamic lateral design loads. The proportion of closure coefficients prescribed by ASCE 7-22 tend to be reasonably conservative in general, and any instances of experimental exceedance of these design values did not appear to affect the design conservatism of Eq. (3). Finally, drag coefficients for rectilinear structures prescribed by ASCE 7-22 appear unrepresentative of coastal structures, which tend to generate column-flow interactions and unbalanced hydrostatic conditions. It is therefore suggested that the flow resistance of such structures be quantified via a bulk resistance coefficient, indicated by recent literature as a more appropriate measure applicable to surface-piercing flow obstructions.

Journal of Structural EngineeringVol. 151(1)
University of Hawaiʻi at Mānoa (US), Louisiana State University (US), Oregon State University (US)
Openalex Percentile: Top 35%
Earthquake and Tsunami Effects
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.