Enhanced approach for three-dimensional myelin-weighted imaging using a novel flow suppression technique in the ViSTa

Motivation: ViSTa offers improved myelin-weighted image. However, the presence of flow artifacts was seen when scanning a subject with a high flow speed. Goal(s): This study aimed to construct a novel 3D ViSTa sequence by implementing a series of flow saturation pulses. Approach: Three flow saturation pulses were placed as evenly as possible between the 1st inversion pulse and the excitation pulse to effectively mitigate the presence of flow with various speeds. Results: The results from the proposed ViSTa sequence reveal a significant reduction in flow artifacts. When we conduct MS patient scans, lesions have a significantly diminished signal level, providing a distinct demarcation. Impact: The proposed method provides improved whole-brain covered 3D myelin-weighted images in a clinically reasonable scan time (< 7 min). Moreover, it shows good sensitivity to MS lesions. These features make the proposed method appealing for clinical neuroimaging applications.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/2978
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced approach for three-dimensional myelin-weighted imaging using a novel flow suppression technique in the ViSTa

Mark J. Lowe, Soleakhena Ken, Sehong Oh, Gawon Lee
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Enhanced approach for three-dimensional myelin-weighted imaging using a novel flow suppression technique in the ViSTa

Mark J. Lowe, Soleakhena Ken, Sehong Oh, Gawon Lee
article en

Abstract

Motivation: ViSTa offers improved myelin-weighted image. However, the presence of flow artifacts was seen when scanning a subject with a high flow speed. Goal(s): This study aimed to construct a novel 3D ViSTa sequence by implementing a series of flow saturation pulses. Approach: Three flow saturation pulses were placed as evenly as possible between the 1st inversion pulse and the excitation pulse to effectively mitigate the presence of flow with various speeds. Results: The results from the proposed ViSTa sequence reveal a significant reduction in flow artifacts. When we conduct MS patient scans, lesions have a significantly diminished signal level, providing a distinct demarcation. Impact: The proposed method provides improved whole-brain covered 3D myelin-weighted images in a clinically reasonable scan time (< 7 min). Moreover, it shows good sensitivity to MS lesions. These features make the proposed method appealing for clinical neuroimaging applications.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.