Development of a transmit gain calibration method using the Bloch-Siegert shift for nonproton hyperpolarized MRI on a preclinical 7T scanner

Motivation: Transmit gain calibration is necessary for nonproton hyperpolarized MRI to accurately calibrate excitation angles. Goal(s): To implement a phase-based TG calibration method using the Bloch-Siegert shift for nonproton HP MRI on a preclinical 7T scanner. Approach: An off-resonance Fermi-shaped Bloch-Siegert pulse follows directly an excitation pulse. Percent difference between our measured Bloch-Siegert TG calibration factors and the validation TG calibration factors for 1H and 13C were calculated. Results: Our method allows for fast, accurate, and robust TG calibration of preclinical nonproton HP MRI studies with minimal error (<5%) for 1H and 13C. Impact: This method will facilitate efficient transmit calibration for 13C and HP 129Xe MRI on a preclinical 7T scanner, where limited bore size and the inability to easily implement a thermal calibration phantom can make 129Xe TG calibration a challenge.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3193
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a transmit gain calibration method using the Bloch-Siegert shift for nonproton hyperpolarized MRI on a preclinical 7T scanner

Collin Harlan, James A. Bankson, Keith A. Michel
1 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Development of a transmit gain calibration method using the Bloch-Siegert shift for nonproton hyperpolarized MRI on a preclinical 7T scanner

Collin Harlan, James A. Bankson, Keith A. Michel
article en

Abstract

Motivation: Transmit gain calibration is necessary for nonproton hyperpolarized MRI to accurately calibrate excitation angles. Goal(s): To implement a phase-based TG calibration method using the Bloch-Siegert shift for nonproton HP MRI on a preclinical 7T scanner. Approach: An off-resonance Fermi-shaped Bloch-Siegert pulse follows directly an excitation pulse. Percent difference between our measured Bloch-Siegert TG calibration factors and the validation TG calibration factors for 1H and 13C were calculated. Results: Our method allows for fast, accurate, and robust TG calibration of preclinical nonproton HP MRI studies with minimal error (<5%) for 1H and 13C. Impact: This method will facilitate efficient transmit calibration for 13C and HP 129Xe MRI on a preclinical 7T scanner, where limited bore size and the inability to easily implement a thermal calibration phantom can make 129Xe TG calibration a challenge.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.