Validation of a High Contrast Technique and T1 Values Obtained by Divided Subtracted Inversion Recovery (dSIR)

Motivation: To validate a 2 point high contrast T1 technique using the National Institute of Standards and Technology (NIST) T1 phantom. Goal(s): Qualitative results produced by the divided subtracted IR (dSIR) images have been shown to give unprecedented T1 contrast in case studies of neuroinflammation [1]. The present study validates the theoretical mechanism of contrast in a standardized commercial T1 phantom. Approach: Experiments were performed at 1.5T to compare the empirical signal response versus the theoretical prediction in a phantom with known T1s. Results: The signal response was found to match the predicted bipolar variation very closely. Impact: Clinicians wishing to employ 2 point T1 estimation techniques can be satisfied that the results are grounded in theory and are quantitatively validated.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3713
Citations
1
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a High Contrast Technique and T1 Values Obtained by Divided Subtracted Inversion Recovery (dSIR)

Mark Bydder, Fadil Ali
1 citations
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Nuclear Physics and Applications
0.61
article

Validation of a High Contrast Technique and T1 Values Obtained by Divided Subtracted Inversion Recovery (dSIR)

Mark Bydder, Fadil Ali
article en
1 citations

Abstract

Motivation: To validate a 2 point high contrast T1 technique using the National Institute of Standards and Technology (NIST) T1 phantom. Goal(s): Qualitative results produced by the divided subtracted IR (dSIR) images have been shown to give unprecedented T1 contrast in case studies of neuroinflammation [1]. The present study validates the theoretical mechanism of contrast in a standardized commercial T1 phantom. Approach: Experiments were performed at 1.5T to compare the empirical signal response versus the theoretical prediction in a phantom with known T1s. Results: The signal response was found to match the predicted bipolar variation very closely. Impact: Clinicians wishing to employ 2 point T1 estimation techniques can be satisfied that the results are grounded in theory and are quantitatively validated.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Partnerships for the goals
Openalex Percentile: Top 28%
Nuclear Physics and Applications
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validation of a High Contrast Technique and T1 Values Obtained by Divided Subtracted Inversion Recovery (dSIR) — Mark Bydder, Fadil Ali · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS