A Single Oscillating Waveform-based Gradient Delay Estimation

Motivation: The study was motivated by substantially reducing the calibration scan time for gradient delay estimation in spiral imaging. Goal(s): we only acquire a single spiral readout along each channel for delay estimation, which enables a substantial reduction in the calibration scan time. Approach: Our proposed method of SODA estimates the delay by calculating the relative shift between the MR spectrums required in a single scan as the k-space trajectory progresses from the negative kx direction to the positive kx direction and vice versa, i.e., from +kx to -kx. Results: The delay values demonstrated robust agreement and consistency between SODA and the reference. Impact: The SODA method delivers accurate delay estimates within extremely short scan time (about 50 ms). This technique can seamlessly integrate with any host sequence to correct k-space location errors stemming from gradient delays.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/4430
Primary Topic
Advanced Photonic Communication Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Single Oscillating Waveform-based Gradient Delay Estimation

John A. Detre, Manuel Taso, Bo Li, Yulin V. Chang et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Photonic Communication Systems
article

A Single Oscillating Waveform-based Gradient Delay Estimation

John A. Detre, Manuel Taso, Bo Li, Yulin V. Chang, Ze Wang
article en

Abstract

Motivation: The study was motivated by substantially reducing the calibration scan time for gradient delay estimation in spiral imaging. Goal(s): we only acquire a single spiral readout along each channel for delay estimation, which enables a substantial reduction in the calibration scan time. Approach: Our proposed method of SODA estimates the delay by calculating the relative shift between the MR spectrums required in a single scan as the k-space trajectory progresses from the negative kx direction to the positive kx direction and vice versa, i.e., from +kx to -kx. Results: The delay values demonstrated robust agreement and consistency between SODA and the reference. Impact: The SODA method delivers accurate delay estimates within extremely short scan time (about 50 ms). This technique can seamlessly integrate with any host sequence to correct k-space location errors stemming from gradient delays.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Life below water
Openalex Percentile: Top 81%
Advanced Photonic Communication Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.