Robust single-point UTE Dixon imaging.

Motivation: A recent approach solved the unwanted phase estimation in single point Dixon imaging using an iterative optimization method. Goal(s): The goal of this work is to properly initialize the previously proposed iterative optimization approach for a more robust water-fat separation. Approach: The iterative optimization method is initialized with the result of the polynomial fit of the signal phase and its derived water and fat signals. Results: By initializing the Gauss Newton method with the result of a polynomial fit of the signal phase, better and more robust water fat separation can be achieved in sUTE Dixon imaging. Impact: The proposed polynomial fit initialization has improved water-fat separation quality and its robustness against regularization parameters while reducing the number of optimization iterations.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0488
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust single-point UTE Dixon imaging.

Dimitrios C. Karampinos, Alexandra S. Gersing, Christof Boehm, Anh T. Van et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Photoacoustic and Ultrasonic Imaging
article

Robust single-point UTE Dixon imaging.

Dimitrios C. Karampinos, Alexandra S. Gersing, Christof Boehm, Anh T. Van, M. Arrieta, Kilian Weiss, Georg C. Feuerriegel
article en

Abstract

Motivation: A recent approach solved the unwanted phase estimation in single point Dixon imaging using an iterative optimization method. Goal(s): The goal of this work is to properly initialize the previously proposed iterative optimization approach for a more robust water-fat separation. Approach: The iterative optimization method is initialized with the result of the polynomial fit of the signal phase and its derived water and fat signals. Results: By initializing the Gauss Newton method with the result of a polynomial fit of the signal phase, better and more robust water fat separation can be achieved in sUTE Dixon imaging. Impact: The proposed polynomial fit initialization has improved water-fat separation quality and its robustness against regularization parameters while reducing the number of optimization iterations.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 80%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Robust single-point UTE Dixon imaging. — Dimitrios C. Karampinos, Alexandra S. Gersing, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS