Spatiotemporal encoding MRI at a portable low field system without parallel imaging

Motivation: Geometric distortions in echo-planar acquisitions pose challenges for correction in portable low-field MRI due to significant field inhomogeneities. Goal(s): Our goal was to apply spatiotemporal encoding (SPEN) MRI at a 110 mT portable low-field system, aiming for nearly distortion-free echo-planar images. Approach: We leveraged the low SAR in low-field MR to optimize the SPEN technique for substantial gains in sensitivity. SPEN-based 2D imaging ,3D imaging and DWI were compared with EPI-based imaging and EPI TopUp correction results. Results: Approximately distortion-free SPEN acquisitions including robust 2D, 3D imaging and DWI demonstrated the potential clinical values of SPEN in the portable low field systems. Impact: SPEN MRI provides a unique and robust fast echo planar acquisition approach to obtain nearly distortion-free images at low-cost portable low field systems, thereby expanding the prospects for rapid imaging, navigation, and functional imaging in portable low-field MRI.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0155
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatiotemporal encoding MRI at a portable low field system without parallel imaging

Ke Dai, Sijie Zhong, Yueqi Qiu, Lucio Frydman et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Spatiotemporal encoding MRI at a portable low field system without parallel imaging

Ke Dai, Sijie Zhong, Yueqi Qiu, Lucio Frydman, Zhiyong Zhang, Hao Chen
article en

Abstract

Motivation: Geometric distortions in echo-planar acquisitions pose challenges for correction in portable low-field MRI due to significant field inhomogeneities. Goal(s): Our goal was to apply spatiotemporal encoding (SPEN) MRI at a 110 mT portable low-field system, aiming for nearly distortion-free echo-planar images. Approach: We leveraged the low SAR in low-field MR to optimize the SPEN technique for substantial gains in sensitivity. SPEN-based 2D imaging ,3D imaging and DWI were compared with EPI-based imaging and EPI TopUp correction results. Results: Approximately distortion-free SPEN acquisitions including robust 2D, 3D imaging and DWI demonstrated the potential clinical values of SPEN in the portable low field systems. Impact: SPEN MRI provides a unique and robust fast echo planar acquisition approach to obtain nearly distortion-free images at low-cost portable low field systems, thereby expanding the prospects for rapid imaging, navigation, and functional imaging in portable low-field MRI.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.