Free-breathing Motion-Corrected Liver DWI at 3T with Optimized Fat-suppression Scheme

Motivation: A free-breathing motion-insensitive and high-quality DWI is desired for abdominal DWI in clinical practice. Goal(s): This study is to propose and evaluate a novel ss-EPI DWI sequence incorporating motion correction , complex averaging , and a combination of a reparametrized sinc fatsat pulse with an optimized water excitation pulse for abdominal DWI. Approach: Four different DWI sequecnes were performed on volunteers. The overall image qualities and the SNR on the liver papernchyma were evaluated and compared. Results: The SNRs of the liver and the image qualities were significantly higher with the proposed Free-breathing motion-corrected DWI ( MOCO-DWI ) sequence compared to other EPI DWI sequences. Impact: The free-breathing MOCO-DWI sequences with complex-averaging and new fat suppression scheme is recommended for high-quality liver DWI in clinical routine.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0196
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Free-breathing Motion-Corrected Liver DWI at 3T with Optimized Fat-suppression Scheme

Enshuang Zheng, Thomas Benkert, Guijin Li, Zhangli Xing et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Free-breathing Motion-Corrected Liver DWI at 3T with Optimized Fat-suppression Scheme

Enshuang Zheng, Thomas Benkert, Guijin Li, Zhangli Xing, Zhiyong Chen, Caixia Fu, Bin Sun, Mingcong Luo, Yunjing Xue
article en

Abstract

Motivation: A free-breathing motion-insensitive and high-quality DWI is desired for abdominal DWI in clinical practice. Goal(s): This study is to propose and evaluate a novel ss-EPI DWI sequence incorporating motion correction , complex averaging , and a combination of a reparametrized sinc fatsat pulse with an optimized water excitation pulse for abdominal DWI. Approach: Four different DWI sequecnes were performed on volunteers. The overall image qualities and the SNR on the liver papernchyma were evaluated and compared. Results: The SNRs of the liver and the image qualities were significantly higher with the proposed Free-breathing motion-corrected DWI ( MOCO-DWI ) sequence compared to other EPI DWI sequences. Impact: The free-breathing MOCO-DWI sequences with complex-averaging and new fat suppression scheme is recommended for high-quality liver DWI in clinical routine.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.