In vivo STEAM and motion compensated spin echo diffusion tensor CMR in multiple cardiac phases: The effect of field strength

Motivation: Diffusion tensor cardiovascular magnetic resonance (DT-CMR) studies described in the literature have almost uniquely been performed at 3T while 1.5T scanners are more widely available. Goal(s): To compare the performance and microstructural parameters available from stimulated echo (STEAM) and motion compensated spin echo (MCSE) DT-CMR sequences at 1.5T and 3T. Approach: DT-CMR was performed in 20 healthy volunteers using both sequences at both field strengths at peak systole and end diastole. Results: MCSE and STEAM sequences are effective at both 1.5T and 3T. STEAM benefits from the increased SNR available at 3T. Impact: DT-CMR studies should consider making use of 1.5T hardware where access to 3T scanners is more difficult particularly where MCSE sequences are to be used with systolic triggering.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0609
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vivo STEAM and motion compensated spin echo diffusion tensor CMR in multiple cardiac phases: The effect of field strength

Andrew D. Scott, Rajkumar Soundarajan, Yaqing Luo, Sònia Nielles‐Vallespin et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

In vivo STEAM and motion compensated spin echo diffusion tensor CMR in multiple cardiac phases: The effect of field strength

Andrew D. Scott, Rajkumar Soundarajan, Yaqing Luo, Sònia Nielles‐Vallespin, Pedro G. Ferreira, Dudley J. Pennell, Ke Wen, Jiahao Huang, Simon Gover
article en

Abstract

Motivation: Diffusion tensor cardiovascular magnetic resonance (DT-CMR) studies described in the literature have almost uniquely been performed at 3T while 1.5T scanners are more widely available. Goal(s): To compare the performance and microstructural parameters available from stimulated echo (STEAM) and motion compensated spin echo (MCSE) DT-CMR sequences at 1.5T and 3T. Approach: DT-CMR was performed in 20 healthy volunteers using both sequences at both field strengths at peak systole and end diastole. Results: MCSE and STEAM sequences are effective at both 1.5T and 3T. STEAM benefits from the increased SNR available at 3T. Impact: DT-CMR studies should consider making use of 1.5T hardware where access to 3T scanners is more difficult particularly where MCSE sequences are to be used with systolic triggering.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Good health and well-being
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.