Fast Spin Echo based T2 Mapping with Point Spread Function Correction

Motivation: Fast Spin Echo (FSE) based method can provide faster T2 mapping compared to the multi-echo spin echo method. However, the varying Point Spread Functions (PSFs) among different echo time images lead to artifacts in the T2 and proton density ($$$\rho$$$) maps. Goal(s): Developing an algorithm to address PSF artifacts in the FSE-based method that enables faster and more accurate T2 mapping. Approach: An optimization process was designed to determine voxel-wise T2 and $$$\rho$$$ values consistent with the acquired data, especially considering various PSFs. Results: The method was validated through simulations, phantom measurements, and mouse brain scans, resulting in improved T2 and $$$\rho$$$ maps. Impact: The method enabled high-quality, fast T2 mapping without the need for any modifications to the FSE pulse sequence. Therefore, it can be readily applied to quantitative studies on subjects that can be imaged with FSE.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3709
Primary Topic
Blind Source Separation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast Spin Echo based T2 Mapping with Point Spread Function Correction

Dan Xiao, Tristhal Parasram
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Blind Source Separation Techniques
article

Fast Spin Echo based T2 Mapping with Point Spread Function Correction

Dan Xiao, Tristhal Parasram
article en

Abstract

Motivation: Fast Spin Echo (FSE) based method can provide faster T2 mapping compared to the multi-echo spin echo method. However, the varying Point Spread Functions (PSFs) among different echo time images lead to artifacts in the T2 and proton density ($$$\rho$$$) maps. Goal(s): Developing an algorithm to address PSF artifacts in the FSE-based method that enables faster and more accurate T2 mapping. Approach: An optimization process was designed to determine voxel-wise T2 and $$$\rho$$$ values consistent with the acquired data, especially considering various PSFs. Results: The method was validated through simulations, phantom measurements, and mouse brain scans, resulting in improved T2 and $$$\rho$$$ maps. Impact: The method enabled high-quality, fast T2 mapping without the need for any modifications to the FSE pulse sequence. Therefore, it can be readily applied to quantitative studies on subjects that can be imaged with FSE.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 76%
Blind Source Separation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.