Development and optimization of deuterium metabolic imaging in the human abdomen at 3T

Motivation: Abdominal imaging of orally-administered deuterium-labelled tracers can be hindered by artifacts arising from excessive stomach signal. Goal(s): To establish and optimize methods for acquisition of abdominal deuterium metabolic imaging in conjunction with orally-administered tracers. Approach: A flexible transmit-receive surface coil was used to image naturally abundant deuterium in healthy volunteers and orally-administered D2O in a patient with renal cancer. Results: Water and lipid peaks were repeatably fit with high confidence both in unlocalised spectra and voxels extracted from MRSI in the liver, kidney, and spleen. Artifacts were minimal even 12 minutes after tracer ingestion. Impact: Feasibility of abdominal deuterium imaging at 3T was demonstrated using a flexible surface coil. We obtained consistent water measurements in healthy volunteers and good images in a patient with a left-sided renal tumour even just 12 min after drinking D2O.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3042
Primary Topic
Chemical Reactions and Isotopes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and optimization of deuterium metabolic imaging in the human abdomen at 3T

Elizabeth Latimer, Mary A. McLean, James Andrew Armitage, Ines Horvat‐Menih et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Chemical Reactions and Isotopes
article

Development and optimization of deuterium metabolic imaging in the human abdomen at 3T

Elizabeth Latimer, Mary A. McLean, James Andrew Armitage, Ines Horvat‐Menih, Ferdia A. Gallagher, Alixander S. Khan, Grant S. Stewart, Marta Wylot, Jonathan R. Birchall, Joshua Kaggie, Huanjun Wang, Thomas J. Mitchell, Ashley Grimmer, Pascal Wodtke, Maria Jesus Zamora Morales
article en

Abstract

Motivation: Abdominal imaging of orally-administered deuterium-labelled tracers can be hindered by artifacts arising from excessive stomach signal. Goal(s): To establish and optimize methods for acquisition of abdominal deuterium metabolic imaging in conjunction with orally-administered tracers. Approach: A flexible transmit-receive surface coil was used to image naturally abundant deuterium in healthy volunteers and orally-administered D2O in a patient with renal cancer. Results: Water and lipid peaks were repeatably fit with high confidence both in unlocalised spectra and voxels extracted from MRSI in the liver, kidney, and spleen. Artifacts were minimal even 12 minutes after tracer ingestion. Impact: Feasibility of abdominal deuterium imaging at 3T was demonstrated using a flexible surface coil. We obtained consistent water measurements in healthy volunteers and good images in a patient with a left-sided renal tumour even just 12 min after drinking D2O.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 84%
Chemical Reactions and Isotopes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.