gSlider-TSE for high-resolution isotropic T2-weighted imaging with high contrast and high SNR

Motivation: Conventional 2D-TSE offers superior tissue contrast compared to 3D-TSE, but its slice thickness is restricted by SNR and slice profile of RF pulse. Goal(s): Our objective was to achieve 0.4mm isotropic T2-weighted imaging with high contrast and high SNR. Approach: Amplitude and phase modulated gSlider pulses were developed and incorporated into 2D-TSE. Their performances were evaluated in phantom and in vivo. Results: The gSlider-TSE achieved 0.4mm isotropic imaging with high accuracy. The SNR was comparable to 8 times averaged conventional 2D-TSE image. Impact: The gSlider-TSE provides high-resolution isotropic imaging with submillimeter slice thickness and high SNR, while preserving the high contrast of conventional 2D-TSE.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3256
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

gSlider-TSE for high-resolution isotropic T2-weighted imaging with high contrast and high SNR

Rui Xue, Yue Wu, Zihao Zhang, Jinyuan Zhang et al.
2 links
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Imaging Techniques and Applications
article

gSlider-TSE for high-resolution isotropic T2-weighted imaging with high contrast and high SNR

Rui Xue, Yue Wu, Zihao Zhang, Jinyuan Zhang, Yan Zhuo
article en

Abstract

Motivation: Conventional 2D-TSE offers superior tissue contrast compared to 3D-TSE, but its slice thickness is restricted by SNR and slice profile of RF pulse. Goal(s): Our objective was to achieve 0.4mm isotropic T2-weighted imaging with high contrast and high SNR. Approach: Amplitude and phase modulated gSlider pulses were developed and incorporated into 2D-TSE. Their performances were evaluated in phantom and in vivo. Results: The gSlider-TSE achieved 0.4mm isotropic imaging with high accuracy. The SNR was comparable to 8 times averaged conventional 2D-TSE image. Impact: The gSlider-TSE provides high-resolution isotropic imaging with submillimeter slice thickness and high SNR, while preserving the high contrast of conventional 2D-TSE.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

gSlider-TSE for high-resolution isotropic T2-weighted imaging with high contrast and high SNR — Rui Xue, Yue Wu, et al. · Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition (2024) | TGRS Research Map | TGRS