Robust water-only liver T1 mapping with Look-Locker spiral out-in-out-in imaging at 0.55T

Motivation: Evaluation of patients with fatty liver disease can benefit from low-field scanners due to their larger bore size and reduced cost. However, fat is a cofounding factor for liver T1 mapping, and there is currently no reliable water-only T1 mapping method for low B0 field strengths. Goal(s): To develop a practical water-only liver T1 mapping method at 0.55T. Approach: Inversion recovery preparation combined with a 3-echo bSSFP spiral out-in-out-in (OIOI) readout was used to obtain water/fat separated images and quantify water-only T1. Results: The proposed water-only T1 mapping method is insensitive to liver PDFF, compared to Cartesian MOLLI and water-fat in-phase T1 values. Impact: For patients with fatty liver disease, this new method provides reliable water-only T1 mapping at low field strength (0.55T). This method may be incorporated into clinical protocols as an indicator of liver inflammation, fibrosis, and stiffness.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0274
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust water-only liver T1 mapping with Look-Locker spiral out-in-out-in imaging at 0.55T

Bilal Taşdelen, Krishna S. Nayak, Ye Tian, Liyun Yuan
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Medical Imaging Techniques and Applications
article

Robust water-only liver T1 mapping with Look-Locker spiral out-in-out-in imaging at 0.55T

Bilal Taşdelen, Krishna S. Nayak, Ye Tian, Liyun Yuan
article en

Abstract

Motivation: Evaluation of patients with fatty liver disease can benefit from low-field scanners due to their larger bore size and reduced cost. However, fat is a cofounding factor for liver T1 mapping, and there is currently no reliable water-only T1 mapping method for low B0 field strengths. Goal(s): To develop a practical water-only liver T1 mapping method at 0.55T. Approach: Inversion recovery preparation combined with a 3-echo bSSFP spiral out-in-out-in (OIOI) readout was used to obtain water/fat separated images and quantify water-only T1. Results: The proposed water-only T1 mapping method is insensitive to liver PDFF, compared to Cartesian MOLLI and water-fat in-phase T1 values. Impact: For patients with fatty liver disease, this new method provides reliable water-only T1 mapping at low field strength (0.55T). This method may be incorporated into clinical protocols as an indicator of liver inflammation, fibrosis, and stiffness.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Clean water and sanitation
Openalex Percentile: Top 63%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.