Slice-to-Volume 4D flow MRI in pediatric patients with congenital heart disease

Motivation: In the absence of injected contrast agent, the quality of magnitude data from traditional 4D flow techniques can be poor, making structural visualization and blood vessel segmentation challenging. Goal(s): Slice-to-volume 4D flow data has inherently high signal in blood vessels owing to in-flow effects. We apply slice-to-volume 4D flow in pediatric patients and evaluate its accuracy. Approach: 7 pediatric patients were imaged with slice-to-volume 4D flow. Dynamic magnitude reconstructions and angiograms were assessed. The flow accuracy was evaluated using traditional 2D phase contrast MRI. Results: Slice-to-volume 4D flow provided accurate flow quantification along with high quality anatomical and angiographic visualisations without contrast injection. Impact: Volumetric flow imaging was performed using slice-to-volume 4D flow in pediatric patients. The technique provided accurate flow quantification along with high quality anatomical and angiographic visualisations without contrast injection.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3394
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Slice-to-Volume 4D flow MRI in pediatric patients with congenital heart disease

Christopher K. Macgowan, Shi‐Joon Yoo, Christopher Lam, Valérie Béland et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Congenital Heart Disease Studies
article

Slice-to-Volume 4D flow MRI in pediatric patients with congenital heart disease

Christopher K. Macgowan, Shi‐Joon Yoo, Christopher Lam, Valérie Béland, Datta Singh Goolaub, Sharon Portnoy
article en

Abstract

Motivation: In the absence of injected contrast agent, the quality of magnitude data from traditional 4D flow techniques can be poor, making structural visualization and blood vessel segmentation challenging. Goal(s): Slice-to-volume 4D flow data has inherently high signal in blood vessels owing to in-flow effects. We apply slice-to-volume 4D flow in pediatric patients and evaluate its accuracy. Approach: 7 pediatric patients were imaged with slice-to-volume 4D flow. Dynamic magnitude reconstructions and angiograms were assessed. The flow accuracy was evaluated using traditional 2D phase contrast MRI. Results: Slice-to-volume 4D flow provided accurate flow quantification along with high quality anatomical and angiographic visualisations without contrast injection. Impact: Volumetric flow imaging was performed using slice-to-volume 4D flow in pediatric patients. The technique provided accurate flow quantification along with high quality anatomical and angiographic visualisations without contrast injection.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
No poverty
Openalex Percentile: Top 68%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.