Rapid, accurate and precise T1 mapping in rat heart at 9.4 T MRI

Motivation: Preclinical cardiac T1 mapping in high field encountered a great challenge, such as rapid heart rate, B0 and B1 inhomogeneity, which affects both accuracy and precision in T1. Goal(s): We aim to develop an accurate, fast and reproducible T1 mapping method at 9.4 T MRI. Approach: We adapted inversion efficiency (IE) to the segmented Look-locker sequence and validated it in a phantom, as well as in aorta banding rats. Results: Segmented Look-Locker T1 mapping with IE is a fast and accurate T1 mapping method, which corrects the imperfection of inversion pulse in high field. Impact: We have developed a rapid, highly precise T1 mapping technique for rat hearts using 9.4 T MRI, enabling longitudinal scans and comparisons between different animals.

Authors

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/3948
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid, accurate and precise T1 mapping in rat heart at 9.4 T MRI

H. Kim, Ida Marie Hauge‐Iversen, Ivar Sjaastad, Einar Sjaastad Nordén et al.
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced MRI Techniques and Applications
article

Rapid, accurate and precise T1 mapping in rat heart at 9.4 T MRI

H. Kim, Ida Marie Hauge‐Iversen, Ivar Sjaastad, Einar Sjaastad Nordén, Lili Zhang
article en

Abstract

Motivation: Preclinical cardiac T1 mapping in high field encountered a great challenge, such as rapid heart rate, B0 and B1 inhomogeneity, which affects both accuracy and precision in T1. Goal(s): We aim to develop an accurate, fast and reproducible T1 mapping method at 9.4 T MRI. Approach: We adapted inversion efficiency (IE) to the segmented Look-locker sequence and validated it in a phantom, as well as in aorta banding rats. Results: Segmented Look-Locker T1 mapping with IE is a fast and accurate T1 mapping method, which corrects the imperfection of inversion pulse in high field. Impact: We have developed a rapid, highly precise T1 mapping technique for rat hearts using 9.4 T MRI, enabling longitudinal scans and comparisons between different animals.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.