Tuned Exchange Imaging (TEXI) – A modified Filter-Exchange Imaging pulse sequence for applications with thin slices and restricted diffusion

Motivation: Thin slices in filter-exchange imaging lead to biased exchange rates, as thin slices require strong crushers. No current approach accounts for crushers in the presence of restricted diffusion. Goal(s): We set to address the bias in FEXI due to the influence of strong crushers and restricted diffusion. Approach: Tuned exchange imaging (TEXI) relies on gauging exchange and restriction weighting. We modify FEXI to ensure constant restriction weighting also with strong crushers. The accuracy of exchange mapping was evaluated using Monte Carlo simulations. Results: TEXI yields consistent exchange rates independent of slice thickness and restriction size even if strong crushers are used. Impact: TEXI could be useful to maximize exchange sensitivity and specificity with thin slices and in the presence of restricted diffusion.

Authors

Institutions

Publication Details

Journal
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Published
2024-11-26
DOI
https://doi.org/10.58530/2024/0601
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tuned Exchange Imaging (TEXI) – A modified Filter-Exchange Imaging pulse sequence for applications with thin slices and restricted diffusion

Henrik Lundell, Arthur Chakwizira, Samo Lasič, Carl‐Fredrik Westin
Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Advanced Electrical Measurement Techniques
article

Tuned Exchange Imaging (TEXI) – A modified Filter-Exchange Imaging pulse sequence for applications with thin slices and restricted diffusion

Henrik Lundell, Arthur Chakwizira, Samo Lasič, Carl‐Fredrik Westin
article en

Abstract

Motivation: Thin slices in filter-exchange imaging lead to biased exchange rates, as thin slices require strong crushers. No current approach accounts for crushers in the presence of restricted diffusion. Goal(s): We set to address the bias in FEXI due to the influence of strong crushers and restricted diffusion. Approach: Tuned exchange imaging (TEXI) relies on gauging exchange and restriction weighting. We modify FEXI to ensure constant restriction weighting also with strong crushers. The accuracy of exchange mapping was evaluated using Monte Carlo simulations. Results: TEXI yields consistent exchange rates independent of slice thickness and restriction size even if strong crushers are used. Impact: TEXI could be useful to maximize exchange sensitivity and specificity with thin slices and in the presence of restricted diffusion.

Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
Technical University of Denmark (DK)
Openalex Percentile: Top 81%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.